Electrochemical investigation of platinum electrode corrosion under neurostimulation protocols

Abstract The long-term stability of the electrode-tissue interface is crucial for neural implant longevity. Platinum is the most commonly used material for stimulation electrodes. To investigate electrode corrosion in neurostimulation, we developed an automated setup combining a preclinically used neurostimulator, a potentiostat, and an oscilloscope to monitor electrode surface state over billions of pulses. Using thin-film platinum electrodes allowed nanometer-scale tracking of material loss via profilometry. Comparing clinically relevant protocols with pulse widths in the microsecond-scale revealed the driving process behind accelerated electrode corrosion to be cyclic oxidation and subsequent reduction of the previously formed surface oxide. Our findings indicate that current-controlled neurostimulation can lead to platinum corrosion, also within common limits of safe stimulation, dependent on the occurring faradaic processes. In situ monitoring of potentials with respect to the electrochemical potential scale and tracking of electrode surface state are crucial for understanding and ultimately preventing electrode corrosion during long-term neurostimulation.

Authors

Institutions

Publication Details

Journal
npj Materials Degradation
Published
2026-04-17
DOI
https://doi.org/10.1038/s41529-026-00789-6
Primary Topic
Neuroscience and Neural Engineering
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrochemical investigation of platinum electrode corrosion under neurostimulation protocols

Andreas Weltin, Moritz Doering, Jochen Kieninger, Nicole Roßkothen-Kuhl et al.
npj Materials Degradation
Neuroscience and Neural Engineering
article

Electrochemical investigation of platinum electrode corrosion under neurostimulation protocols

Andreas Weltin, Moritz Doering, Jochen Kieninger, Nicole Roßkothen-Kuhl, Ulrich Hofmann, Stefan J. Rupitsch, Stefan Reinelt
article en

Abstract

Abstract The long-term stability of the electrode-tissue interface is crucial for neural implant longevity. Platinum is the most commonly used material for stimulation electrodes. To investigate electrode corrosion in neurostimulation, we developed an automated setup combining a preclinically used neurostimulator, a potentiostat, and an oscilloscope to monitor electrode surface state over billions of pulses. Using thin-film platinum electrodes allowed nanometer-scale tracking of material loss via profilometry. Comparing clinically relevant protocols with pulse widths in the microsecond-scale revealed the driving process behind accelerated electrode corrosion to be cyclic oxidation and subsequent reduction of the previously formed surface oxide. Our findings indicate that current-controlled neurostimulation can lead to platinum corrosion, also within common limits of safe stimulation, dependent on the occurring faradaic processes. In situ monitoring of potentials with respect to the electrochemical potential scale and tracking of electrode surface state are crucial for understanding and ultimately preventing electrode corrosion during long-term neurostimulation.

npj Materials DegradationVol. 10(1)
University of Freiburg (DE), University Medical Center Freiburg (DE), Bernstein Center for Computational Neuroscience Freiburg (DE), Brain (Germany) (DE)
Deutsche Forschungsgemeinschaft
Openalex Percentile: Top 20%
Neuroscience and Neural Engineering
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.