Development of Prosthetic Robotic Hand Using EMG Sensor for Upper-Limb Amputees

Conventional body-powered systems eventually suffer from the limitations of the relatively low force and dexterity these can offer while requiring strenuous exertion to operate, and advanced myoelectric systems tend to rely on complex algorithms and expensive hardware and calibration routines. These challenges present significant barriers to access of functional prosthetic hands for upper-limb amputees. This paper presents an EMG-controlled three-fingered prosthetic robotic hand based on non-invasive surface electromyography signals from healthy distal residual forearm muscles. The proposed system integrates analog signal conditioning, time-domain feature extraction (Mean Absolute Value) and threshold-based classification to enable Arduino-based real-time processing for servo-driven mechanical actuation. The system achieves 92.5% single-gesture and 88.4% multi-gesture accuracy, with a total average response time of 290 ms, confirming that simplified embedded control can deliver performance and reliability for practical prosthetic functionality in a daily-assist device.

Authors

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2026-04-16
DOI
https://doi.org/10.1051/epjconf/202636302003/pdf
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of Prosthetic Robotic Hand Using EMG Sensor for Upper-Limb Amputees

Imran Hussain S, S Kaviyarasan, Jaisri J
Springer Link (Chiba Institute of Technology)
Muscle activation and electromyography studies
article

Development of Prosthetic Robotic Hand Using EMG Sensor for Upper-Limb Amputees

Imran Hussain S, S Kaviyarasan, Jaisri J
article en

Abstract

Conventional body-powered systems eventually suffer from the limitations of the relatively low force and dexterity these can offer while requiring strenuous exertion to operate, and advanced myoelectric systems tend to rely on complex algorithms and expensive hardware and calibration routines. These challenges present significant barriers to access of functional prosthetic hands for upper-limb amputees. This paper presents an EMG-controlled three-fingered prosthetic robotic hand based on non-invasive surface electromyography signals from healthy distal residual forearm muscles. The proposed system integrates analog signal conditioning, time-domain feature extraction (Mean Absolute Value) and threshold-based classification to enable Arduino-based real-time processing for servo-driven mechanical actuation. The system achieves 92.5% single-gesture and 88.4% multi-gesture accuracy, with a total average response time of 290 ms, confirming that simplified embedded control can deliver performance and reliability for practical prosthetic functionality in a daily-assist device.

Springer Link (Chiba Institute of Technology)
Openalex Percentile: Top 15%
Muscle activation and electromyography studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.