Structural and Computational Validation of a Novel Titanium Scleral Buckle Implant for Posterior Pole Retinal Detachment

Background: A novel titanium scleral buckle implant (TSBI) was developed for the treatment of posterior pole retinal detachments, analytically modeled and structurally tested as part of preclinical approval studies. The strength and stiffness requirements to apply pressure for retinal reattachment also suggested potential benefits for correcting high myopia greater than 8 diopters. Methods: Laboratory load testing and analytical calculations were complemented by nonlinear finite element modeling (FEM), applied for the first time to capture the interaction between the highly deformed myopic eye and the TSBI. Simulations were used to visualize posterior pole indentation and force distribution across anatomical regions. Seven TSBI units were tested in the transverse direction and six in the longitudinal direction. Results: The simulations confirmed that stable indentation is maintained even in areas distant from the sutures. The TSBI’s minimum midspan bending capacity was 40 N at yield and 60 N at ultimate. These values, together with FEM predictions, demonstrated a very large safety margin and showed that the implant deforms insignificantly under high intraocular pressure changes. Conclusions: The TSBI withstands ocular forces, cushions the sclera safely, and retains its geometry, a behavior that may differ from softer buckle materials, which can exhibit time-dependent deformation under sustained loading. Early controlled clinical applications outside the USA, followed for over three years, further validate its safety and potential effectiveness.

Authors

Institutions

Publication Details

Journal
Journal of Clinical & Translational Ophthalmology
Published
2026-04-17
DOI
https://doi.org/10.3390/jcto4020011
Primary Topic
Retinal and Macular Surgery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Structural and Computational Validation of a Novel Titanium Scleral Buckle Implant for Posterior Pole Retinal Detachment

Levent Akduman, Ahmet Türer, Tugce Ilayda Turer
Journal of Clinical & Translational Ophthalmology
Retinal and Macular Surgery
article

Structural and Computational Validation of a Novel Titanium Scleral Buckle Implant for Posterior Pole Retinal Detachment

Levent Akduman, Ahmet Türer, Tugce Ilayda Turer
article en

Abstract

Background: A novel titanium scleral buckle implant (TSBI) was developed for the treatment of posterior pole retinal detachments, analytically modeled and structurally tested as part of preclinical approval studies. The strength and stiffness requirements to apply pressure for retinal reattachment also suggested potential benefits for correcting high myopia greater than 8 diopters. Methods: Laboratory load testing and analytical calculations were complemented by nonlinear finite element modeling (FEM), applied for the first time to capture the interaction between the highly deformed myopic eye and the TSBI. Simulations were used to visualize posterior pole indentation and force distribution across anatomical regions. Seven TSBI units were tested in the transverse direction and six in the longitudinal direction. Results: The simulations confirmed that stable indentation is maintained even in areas distant from the sutures. The TSBI’s minimum midspan bending capacity was 40 N at yield and 60 N at ultimate. These values, together with FEM predictions, demonstrated a very large safety margin and showed that the implant deforms insignificantly under high intraocular pressure changes. Conclusions: The TSBI withstands ocular forces, cushions the sclera safely, and retains its geometry, a behavior that may differ from softer buckle materials, which can exhibit time-dependent deformation under sustained loading. Early controlled clinical applications outside the USA, followed for over three years, further validate its safety and potential effectiveness.

Journal of Clinical & Translational OphthalmologyVol. 4(2)
Middle East Technical University (TR), Associated Eyecare (US)
Openalex Percentile: Top 9%
Retinal and Macular Surgery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.