Accuracy of Static Computer-Aided Implant Surgery: A Clinical Comparison of Tooth-, Bone-, and Mucosa-Supported Surgical Guides

< 0.001). Tooth-supported guides demonstrated the highest level of accuracy, with a mean angular deviation of 1.81° ± 0.45° and linear deviations at the neck and apex of 0.59 ± 0.18 mm and 0.73 ± 0.19 mm, respectively. These were followed by bone-supported guides (2.14° ± 0.48°; 1.04 ± 0.26 mm; 1.61 ± 0.31 mm), while mucosa-supported guides exhibited the greatest deviations (2.95° ± 0.60°; 1.47 ± 0.29 mm; 1.87 ± 0.37 mm). Significant intergroup differences and large effect sizes were observed, particularly regarding angular and horizontal discrepancies. These findings demonstrate a distinct gradient of accuracy based on guide support, establishing tooth-supported guides as the most accurate, followed by bone-supported and, lastly, mucosa-supported guides. While all modalities are clinically applicable, the use of mucosa-supported guides necessitates increased safety margins to account for the increased risk of linear and angular discrepancies inherent to mucosal tissue displacement.

Authors

Institutions

Publication Details

Journal
Journal of Functional Biomaterials
Published
2026-04-17
DOI
https://doi.org/10.3390/jfb17040194
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy of Static Computer-Aided Implant Surgery: A Clinical Comparison of Tooth-, Bone-, and Mucosa-Supported Surgical Guides

I SMOJVER, Roko Bjelica, Marko Vuletić, Vlatka Njari Galić et al.
Journal of Functional Biomaterials
Dental Implant Techniques and Outcomes
article

Accuracy of Static Computer-Aided Implant Surgery: A Clinical Comparison of Tooth-, Bone-, and Mucosa-Supported Surgical Guides

I SMOJVER, Roko Bjelica, Marko Vuletić, Vlatka Njari Galić, Luka Stojić, Dragana Gabrić
article en

Abstract

< 0.001). Tooth-supported guides demonstrated the highest level of accuracy, with a mean angular deviation of 1.81° ± 0.45° and linear deviations at the neck and apex of 0.59 ± 0.18 mm and 0.73 ± 0.19 mm, respectively. These were followed by bone-supported guides (2.14° ± 0.48°; 1.04 ± 0.26 mm; 1.61 ± 0.31 mm), while mucosa-supported guides exhibited the greatest deviations (2.95° ± 0.60°; 1.47 ± 0.29 mm; 1.87 ± 0.37 mm). Significant intergroup differences and large effect sizes were observed, particularly regarding angular and horizontal discrepancies. These findings demonstrate a distinct gradient of accuracy based on guide support, establishing tooth-supported guides as the most accurate, followed by bone-supported and, lastly, mucosa-supported guides. While all modalities are clinically applicable, the use of mucosa-supported guides necessitates increased safety margins to account for the increased risk of linear and angular discrepancies inherent to mucosal tissue displacement.

Journal of Functional BiomaterialsVol. 17(4)
University Hospital Centre Zagreb (HR), University of Zagreb (HR), Zdravstveni centar (RS), Klinik und Poliklinik für Mund-, Kiefer- und Gesichtschirurgie (DE)
Openalex Percentile: Top 19%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.