Experimental and Finite Element Investigation of Bolted Connections in GFRP Composite Cross-Arms for Energy Distribution Towers

This study investigates bolted connections in open-section glass fiber-reinforced polymer (GFRP) composite cross-arms for 34.5 kV energy distribution towers. Six GFRP angle sections (L50 × 5 to L120 × 12) were tested under tensile loading using a constant edge distance-to-bolt diameter ratio (e/d = 5), and the connection performance was evaluated based on general maximum and deformation-based criteria (4% and 1 mm hole elongation). Connection capacities ranged from 14.65 to 36.68 kN for single-bolt configurations. Results from multi-bolt connections tests indicated strong influence of bolt layout on connection performance. The highest load capacities of 46.45 kN and 45.93 kN were obtained, respectively, with the two-row bolt configuration and staggered configuration. Comparison of the measured load capacities with ASCE/SEI 74-23 predictions revealed significant discrepancies depending on the assumed failure mode of the connection. A simplified finite element model was developed to predict load-displacement response, capturing initial stiffness and overall trends with reasonable agreement, particularly for connections exhibiting similar failure modes. The findings provide a reliable basis for selecting appropriate bolted connection details in open-section GFRP cross-arm systems.

Authors

Institutions

Publication Details

Journal
Polymers
Published
2026-04-17
DOI
https://doi.org/10.3390/polym18080978
Primary Topic
Structural Response to Dynamic Loads
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental and Finite Element Investigation of Bolted Connections in GFRP Composite Cross-Arms for Energy Distribution Towers

Eray Baran, Burak Talha Kilic
Polymers
Structural Response to Dynamic Loads
article

Experimental and Finite Element Investigation of Bolted Connections in GFRP Composite Cross-Arms for Energy Distribution Towers

Eray Baran, Burak Talha Kilic
article en

Abstract

This study investigates bolted connections in open-section glass fiber-reinforced polymer (GFRP) composite cross-arms for 34.5 kV energy distribution towers. Six GFRP angle sections (L50 × 5 to L120 × 12) were tested under tensile loading using a constant edge distance-to-bolt diameter ratio (e/d = 5), and the connection performance was evaluated based on general maximum and deformation-based criteria (4% and 1 mm hole elongation). Connection capacities ranged from 14.65 to 36.68 kN for single-bolt configurations. Results from multi-bolt connections tests indicated strong influence of bolt layout on connection performance. The highest load capacities of 46.45 kN and 45.93 kN were obtained, respectively, with the two-row bolt configuration and staggered configuration. Comparison of the measured load capacities with ASCE/SEI 74-23 predictions revealed significant discrepancies depending on the assumed failure mode of the connection. A simplified finite element model was developed to predict load-displacement response, capturing initial stiffness and overall trends with reasonable agreement, particularly for connections exhibiting similar failure modes. The findings provide a reliable basis for selecting appropriate bolted connection details in open-section GFRP cross-arm systems.

PolymersVol. 18(8)
Middle East Technical University (TR)
Affordable and clean energy
Openalex Percentile: Top 20%
Structural Response to Dynamic Loads
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.