Repeatability of automated body composition measurement on low dose chest CT in male subjects

BACKGROUND: The objective was to determine the most repeatable of three automated body composition methods applied to baseline and short-term follow-up chest CT scans. METHODS: Areas of skeletal muscle and subcutaneous adipose tissue (SAT) were analyzed in a 1 mm slice close to the aortic arch in a subset of males from the NELSON lung cancer screening trial with baseline and 3-4 month repeat CT scan. We compared three pre-existing machine learning methods we call: truncated field of view (FOV), compensated FOV, and extended FOV, of which the last two can deal with non-overlapping FOV in scans. Repeatability was assessed using Bland-Altman plots and paired T-tests. RESULTS: Of 562 males the median (interquartile range) age was 60.8 (56.3-64.8) years. Mean skeletal muscle areas were similar for truncated (212 cm²) and extended FOV (211 cm²), and slightly lower for compensated FOV (208 cm²) (p < 0.001). SAT areas were higher with extended FOV (156 cm²) compared to truncated (132 cm²) and compensated FOV (125 cm²) (p < 0.001). A small systematic longitudinal difference in skeletal muscle was observed for extended FOV (mean±SD 1.7 ± 17.3 cm2, p = 0.017). Limits of agreement for skeletal muscle area were -18.9% to 20.4% for truncated FOV, -11.1% to 11.6% for compensated FOV, and -16.7% to 18.2% for extended FOV. Corresponding values for SAT area were -37.3% to 38.3%,-30.2% to 29.3%, and -29.1% to 29.9%. CONCLUSION: Extended FOV had the second-most repeatable measurements and was unaffected by FOV cutoff. Compensated FOV was most repeatable, but underestimated SAT.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2026-04-17
DOI
https://doi.org/10.1371/journal.pone.0332004
Citations
1
Primary Topic
Nutrition and Health in Aging
Type
article
Field-Weighted Citation Impact
19.92

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Repeatability of automated body composition measurement on low dose chest CT in male subjects

Firdaus Mohamed Hoesein, Edwin Bennink, Harry Groen, Grigory Sidorenkov et al.
1 citations
PLoS ONE
Nutrition and Health in Aging
19.92
article

Repeatability of automated body composition measurement on low dose chest CT in male subjects

Firdaus Mohamed Hoesein, Edwin Bennink, Harry Groen, Grigory Sidorenkov, Schuuring, Stijn Bunk, Pim A. de Jong, Hester Gietema, Rozemarijn Vliegenthart
article en
1 citations

Abstract

BACKGROUND: The objective was to determine the most repeatable of three automated body composition methods applied to baseline and short-term follow-up chest CT scans. METHODS: Areas of skeletal muscle and subcutaneous adipose tissue (SAT) were analyzed in a 1 mm slice close to the aortic arch in a subset of males from the NELSON lung cancer screening trial with baseline and 3-4 month repeat CT scan. We compared three pre-existing machine learning methods we call: truncated field of view (FOV), compensated FOV, and extended FOV, of which the last two can deal with non-overlapping FOV in scans. Repeatability was assessed using Bland-Altman plots and paired T-tests. RESULTS: Of 562 males the median (interquartile range) age was 60.8 (56.3-64.8) years. Mean skeletal muscle areas were similar for truncated (212 cm²) and extended FOV (211 cm²), and slightly lower for compensated FOV (208 cm²) (p < 0.001). SAT areas were higher with extended FOV (156 cm²) compared to truncated (132 cm²) and compensated FOV (125 cm²) (p < 0.001). A small systematic longitudinal difference in skeletal muscle was observed for extended FOV (mean±SD 1.7 ± 17.3 cm2, p = 0.017). Limits of agreement for skeletal muscle area were -18.9% to 20.4% for truncated FOV, -11.1% to 11.6% for compensated FOV, and -16.7% to 18.2% for extended FOV. Corresponding values for SAT area were -37.3% to 38.3%,-30.2% to 29.3%, and -29.1% to 29.9%. CONCLUSION: Extended FOV had the second-most repeatable measurements and was unaffected by FOV cutoff. Compensated FOV was most repeatable, but underestimated SAT.

PLoS ONEVol. 21(4)
University Medical Center Groningen (NL), University of Groningen (NL), Utrecht University (NL), University Medical Center Utrecht (NL), Maastricht University (NL)
Health~Holland, KWF Kankerbestrijding, Siemens Healthineers, Ministerie van Economische Zaken en Klimaat
Openalex Percentile: Top 1%
Nutrition and Health in Aging
19.92
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.