Incipient Fault Diagnosis in Power Cables Based on WOA-CEEMDAN and a TCN-BiLSTM Network with Multi-Head Attention

Incipient faults in power cables are difficult to diagnose because their transient signatures are weak, non-stationary, and easily masked by background noise, while labeled real-world samples are often scarce. To address these challenges, this paper proposes an offline diagnosis framework that integrates Whale Optimization Algorithm (WOA)-guided CEEMDAN with a TCN-BiLSTM-Multi-HeadAttention network. The proposed method has three main features. First, WOA is explicitly mapped to the CEEMDAN parameter optimization problem and is used to adaptively optimize the noise amplitude and ensemble number, thereby improving decomposition quality and enhancing weak fault-related components. Second, the optimized intrinsic mode functions are reconstructed into a multi-channel representation that preserves complementary fault information across different frequency bands. Third, a hybrid deep architecture combining Temporal Convolutional Networks, Bidirectional Long Short-Term Memory, and multi-HeadAttention is designed to jointly capture local transient characteristics, bidirectional temporal dependencies, and fault-sensitive feature interactions. Experimental results on both PSCAD/EMTDC simulation data and real-world measured data show that the optimized WOA-CEEMDAN achieves superior decomposition performance, with an RMSE of 0.097 and an SNR of 8.42 dB. On the real-world test dataset, the proposed framework achieves 96.00% accuracy, 97.25% precision, 96.84% recall, an F1-score of 0.970, and an AUC of 0.97, outperforming several representative baseline models. Additional ablation, noise-robustness, small-sample, confusion-matrix, and cross-cable validation results further demonstrate the effectiveness and robustness of the proposed framework for incipient cable fault diagnosis.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2026-04-17
DOI
https://doi.org/10.3390/app16083908
Primary Topic
Electrical Fault Detection and Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Incipient Fault Diagnosis in Power Cables Based on WOA-CEEMDAN and a TCN-BiLSTM Network with Multi-Head Attention

Yuhua Xing, Yaolong Yin
Applied Sciences
Electrical Fault Detection and Protection
article

Incipient Fault Diagnosis in Power Cables Based on WOA-CEEMDAN and a TCN-BiLSTM Network with Multi-Head Attention

Yuhua Xing, Yaolong Yin
article en

Abstract

Incipient faults in power cables are difficult to diagnose because their transient signatures are weak, non-stationary, and easily masked by background noise, while labeled real-world samples are often scarce. To address these challenges, this paper proposes an offline diagnosis framework that integrates Whale Optimization Algorithm (WOA)-guided CEEMDAN with a TCN-BiLSTM-Multi-HeadAttention network. The proposed method has three main features. First, WOA is explicitly mapped to the CEEMDAN parameter optimization problem and is used to adaptively optimize the noise amplitude and ensemble number, thereby improving decomposition quality and enhancing weak fault-related components. Second, the optimized intrinsic mode functions are reconstructed into a multi-channel representation that preserves complementary fault information across different frequency bands. Third, a hybrid deep architecture combining Temporal Convolutional Networks, Bidirectional Long Short-Term Memory, and multi-HeadAttention is designed to jointly capture local transient characteristics, bidirectional temporal dependencies, and fault-sensitive feature interactions. Experimental results on both PSCAD/EMTDC simulation data and real-world measured data show that the optimized WOA-CEEMDAN achieves superior decomposition performance, with an RMSE of 0.097 and an SNR of 8.42 dB. On the real-world test dataset, the proposed framework achieves 96.00% accuracy, 97.25% precision, 96.84% recall, an F1-score of 0.970, and an AUC of 0.97, outperforming several representative baseline models. Additional ablation, noise-robustness, small-sample, confusion-matrix, and cross-cable validation results further demonstrate the effectiveness and robustness of the proposed framework for incipient cable fault diagnosis.

Applied SciencesVol. 16(8)
Xi'an University of Technology (CN)
Life below water
Openalex Percentile: Top 21%
Electrical Fault Detection and Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.