Autofeelment: Design and Development of an Automated Monofilament Testing Device for Peripheral Diabetic Neuropathy

Abstract Peripheral diabetic neuropathy is a common complication of diabetes mellitus and is associated with progressive loss of protective sensation in the feet, increasing the risk of ulcers and lower-limb complications. The Semmes–Weinstein monofilament test is widely used to assess protective sensation; however, variability in manual administration may affect consistency in test delivery across settings. This study presents the design, development, and mechanical validation of Autofeelment, an automated device intended to standardize the application of the monofilament test through controlled actuation and sequencing. The device consists of a mechanical platform with four linear actuators, a microcontroller-based control system, and a smartphone interface to enable automated testing at predefined plantar locations. Mechanical validation was conducted using healthy volunteers to assess timing consistency, actuator performance, and usability. Ten participants each completed three consecutive testing trials, resulting in 30 validation trials and 120 actuator extensions. The device demonstrated a mean testing time of 10.409±0.019 s, corresponding to a coefficient of variation of 0.18%. Successful monofilament buckling was achieved in 118 of 120 actuator extensions (98.3%). Participants reported high levels of comfort (mean 4.6/5) and ease of use (mean 4.8/5), with no adverse events observed. These findings demonstrate the mechanical reliability, temporal consistency, and usability of the Autofeelment device as a prototype system. This study does not evaluate diagnostic accuracy or clinical effectiveness. Further work is required to validate automated monofilament testing in diabetic populations and to compare performance with standard manual testing methods.

Authors

Institutions

Publication Details

Journal
Journal of Medical Devices
Published
2026-04-17
DOI
https://doi.org/10.1115/1.4071690
Primary Topic
Diabetic Foot Ulcer Assessment and Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Autofeelment: Design and Development of an Automated Monofilament Testing Device for Peripheral Diabetic Neuropathy

Ilesh / Veliah Sundar, Geetha Veliah
Journal of Medical Devices
Diabetic Foot Ulcer Assessment and Management
article

Autofeelment: Design and Development of an Automated Monofilament Testing Device for Peripheral Diabetic Neuropathy

Ilesh / Veliah Sundar, Geetha Veliah
article en

Abstract

Abstract Peripheral diabetic neuropathy is a common complication of diabetes mellitus and is associated with progressive loss of protective sensation in the feet, increasing the risk of ulcers and lower-limb complications. The Semmes–Weinstein monofilament test is widely used to assess protective sensation; however, variability in manual administration may affect consistency in test delivery across settings. This study presents the design, development, and mechanical validation of Autofeelment, an automated device intended to standardize the application of the monofilament test through controlled actuation and sequencing. The device consists of a mechanical platform with four linear actuators, a microcontroller-based control system, and a smartphone interface to enable automated testing at predefined plantar locations. Mechanical validation was conducted using healthy volunteers to assess timing consistency, actuator performance, and usability. Ten participants each completed three consecutive testing trials, resulting in 30 validation trials and 120 actuator extensions. The device demonstrated a mean testing time of 10.409±0.019 s, corresponding to a coefficient of variation of 0.18%. Successful monofilament buckling was achieved in 118 of 120 actuator extensions (98.3%). Participants reported high levels of comfort (mean 4.6/5) and ease of use (mean 4.8/5), with no adverse events observed. These findings demonstrate the mechanical reliability, temporal consistency, and usability of the Autofeelment device as a prototype system. This study does not evaluate diagnostic accuracy or clinical effectiveness. Further work is required to validate automated monofilament testing in diabetic populations and to compare performance with standard manual testing methods.

Journal of Medical DevicesVol. 20(5)
SRM Institute of Science and Technology (IN), San Jose State University (US), San Jose City College (US), Bellarmine University (US)
Good health and well-being
Openalex Percentile: Top 25%
Diabetic Foot Ulcer Assessment and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.