Measurements of efficiency, timing and response to irradiation for direct detection of charged particles with SiPMs

Abstract In this paper, the efficiency of direct charged particle detection with different silicon photomultiplier (SiPM) sensors has been measured to be close to 100%. A time resolution of about 20 ps has also been confirmed for sensors with an active area of about 3 $$\times$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mo>×</mml:mo> </mml:math> 3 $$\hbox {mm}^{\text {2}}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:msup> <mml:mtext>mm</mml:mtext> <mml:mtext>2</mml:mtext> </mml:msup> </mml:math> and a single-cell pitch of area of 40 $$\times$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mo>×</mml:mo> </mml:math> 40 µ $$\hbox {m}^{\text {2}}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:msup> <mml:mtext>m</mml:mtext> <mml:mtext>2</mml:mtext> </mml:msup> </mml:math> . In addition, the SiPM performance after irradiation, in terms of timing response and dark count rate, has been evaluated for sensors with a 1 $$\times$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mo>×</mml:mo> </mml:math> 1 $$\hbox {mm}^{\text {2}}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:msup> <mml:mtext>mm</mml:mtext> <mml:mtext>2</mml:mtext> </mml:msup> </mml:math> area, demonstrating that SiPMs can maintain excellent timing capabilities and a low dark count rate when an appropriate threshold is applied to the signal.

Authors

Institutions

Publication Details

Journal
The European Physical Journal Plus
Published
2026-04-17
DOI
https://doi.org/10.1140/epjp/s13360-026-07578-9
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurements of efficiency, timing and response to irradiation for direct detection of charged particles with SiPMs

F. Ercolessi, S. Tomassini, S. Durando, F. Carnesecchi et al.
The European Physical Journal Plus
Radiation Detection and Scintillator Technologies
article

Measurements of efficiency, timing and response to irradiation for direct detection of charged particles with SiPMs

F. Ercolessi, S. Tomassini, S. Durando, F. Carnesecchi, C. Veri, D. Cavazza, A. Alici, G. Gioachin, S. Strazzi, G. Clai, I. Lax, A Rivetti, M. Maestrelli, G. Fabbri, M. Penna, B. Sabiu, G. Romanenko, M. Razza, E. Scapparone, N. Agrawal, C. Baldanza, S. Geminiani, N. Rubini, B.R. Achari, U. Follo, L. Parellada-Monreal, L. Rignanese, G. Scioli, S. Arcelli, C. Ferrero, P. Antonioli, A. Ficorella, E. Rovati, F. Bellini, A. Zichichi, R. Preghenella, G. Malfattore, S. Bufalino, M. Garbini, D. Hatzifotiadou, D. Falchieri, M. Colocci, R. Nania, A. Margotti, A. Khuntia, A. Gola, F. Noferini, O. Pinazza, R. Ricci, L. Cifarelli
article en

Abstract

Abstract In this paper, the efficiency of direct charged particle detection with different silicon photomultiplier (SiPM) sensors has been measured to be close to 100%. A time resolution of about 20 ps has also been confirmed for sensors with an active area of about 3 $$\times$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mo>×</mml:mo> </mml:math> 3 $$\hbox {mm}^{\text {2}}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:msup> <mml:mtext>mm</mml:mtext> <mml:mtext>2</mml:mtext> </mml:msup> </mml:math> and a single-cell pitch of area of 40 $$\times$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mo>×</mml:mo> </mml:math> 40 µ $$\hbox {m}^{\text {2}}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:msup> <mml:mtext>m</mml:mtext> <mml:mtext>2</mml:mtext> </mml:msup> </mml:math> . In addition, the SiPM performance after irradiation, in terms of timing response and dark count rate, has been evaluated for sensors with a 1 $$\times$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mo>×</mml:mo> </mml:math> 1 $$\hbox {mm}^{\text {2}}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:msup> <mml:mtext>mm</mml:mtext> <mml:mtext>2</mml:mtext> </mml:msup> </mml:math> area, demonstrating that SiPMs can maintain excellent timing capabilities and a low dark count rate when an appropriate threshold is applied to the signal.

The European Physical Journal PlusVol. 141(4)
Politecnico di Torino (IT), Fondazione Bruno Kessler (IT), Istituto Nazionale di Fisica Nucleare, Sezione di Lecce (IT), Istituto Nazionale di Fisica Nucleare, Sezione di Torino (IT), Centro Ricerche Enrico Fermi (IT), Istituto Nazionale di Fisica Nucleare, Sezione di Bologna (IT), National Agency for New Technologies Energy and Sustainable Economic Development (GB), University of Bologna (IT)
Fondazione Bruno Kessler, Università di Bologna, HORIZON EUROPE Framework Programme, Instituto Nazionale di Fisica Nucleare, HORIZON EUROPE European Innovation Council
Openalex Percentile: Top 10%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.