Sensor-Independent One-Hour-Ahead Forecasting and Anomaly Detection of Grid-Connected PV Inverters Using an Interpretable Random Forest Framework

Dependable tracking of grid-linked photovoltaic (PV) systems is also unfeasible because it relies on meteorological sensors and rule-based management, especially in sensorlimited situations. The study constructs a machine learning model interpretable to humans based on electrical measurements of a PV plant of 30 kW and 40 kW inverters, and a five-minute resolution dataset of active and reactive power, phase voltages and phase currents and time dependent features during January 2025. An application of the regression, classification, and Z-score anomaly detection method was conducted using the Random Forest and conditioned on the timestamp alignment, feature engineering, percentile-based categorization of the output, and a one-hour-ahead label shifting, and the method was validated with the aid of the temporal splits and 5-fold Time Series cross-validation. The regression model was found to have great predictive accuracy (MAE = 0.12 kW, R2 = 0.995), and cross-validation performed showed great robustness (R2 = 0.9802, MAE = 0.1024 kW). The Z-score analysis (z = 3) revealed the presence of anomalous samples (2.77%). Though the accuracy of a static classification was 86 percent, time-varying forecasting lowered the accuracy to 33 % ( macro F1 = 0.33) which points to the impact of dynamic environmental variability. The suggested light and interpretable structure allows predicting the performance of inverters in real-time, early detecting anomalies, and intelligent planning of PV systems maintenance without the use of external meteorological devices.

Authors

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2026-04-16
DOI
https://doi.org/10.1051/epjconf/202636301022/pdf
Primary Topic
Photovoltaic System Optimization Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sensor-Independent One-Hour-Ahead Forecasting and Anomaly Detection of Grid-Connected PV Inverters Using an Interpretable Random Forest Framework

S. Mayakannan, Sriharini B, S. Arunkumar, N. M. Anoop Krishnan et al.
Springer Link (Chiba Institute of Technology)
Photovoltaic System Optimization Techniques
article

Sensor-Independent One-Hour-Ahead Forecasting and Anomaly Detection of Grid-Connected PV Inverters Using an Interpretable Random Forest Framework

S. Mayakannan, Sriharini B, S. Arunkumar, N. M. Anoop Krishnan, P. Meruna, A. John Pradeep Ebenezer
article en

Abstract

Dependable tracking of grid-linked photovoltaic (PV) systems is also unfeasible because it relies on meteorological sensors and rule-based management, especially in sensorlimited situations. The study constructs a machine learning model interpretable to humans based on electrical measurements of a PV plant of 30 kW and 40 kW inverters, and a five-minute resolution dataset of active and reactive power, phase voltages and phase currents and time dependent features during January 2025. An application of the regression, classification, and Z-score anomaly detection method was conducted using the Random Forest and conditioned on the timestamp alignment, feature engineering, percentile-based categorization of the output, and a one-hour-ahead label shifting, and the method was validated with the aid of the temporal splits and 5-fold Time Series cross-validation. The regression model was found to have great predictive accuracy (MAE = 0.12 kW, R2 = 0.995), and cross-validation performed showed great robustness (R2 = 0.9802, MAE = 0.1024 kW). The Z-score analysis (z = 3) revealed the presence of anomalous samples (2.77%). Though the accuracy of a static classification was 86 percent, time-varying forecasting lowered the accuracy to 33 % ( macro F1 = 0.33) which points to the impact of dynamic environmental variability. The suggested light and interpretable structure allows predicting the performance of inverters in real-time, early detecting anomalies, and intelligent planning of PV systems maintenance without the use of external meteorological devices.

Springer Link (Chiba Institute of Technology)
Openalex Percentile: Top 21%
Photovoltaic System Optimization Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.