Comparative evaluation of ammonium chloride-modified and hospital-grade activated charcoal for paracetamol adsorption under simulated gastric (pepsin) and intestinal (pancreatin) fluid

INTRODUCTION: wood, with hospital-grade activated charcoal in simulated gastric and intestinal fluid. METHODS: Adsorption experiments were conducted using 20 mg of activated charcoal, in a paracetamol solution containing 2.5 mg of paracetamol (50 mg/L in 50 mL), corresponding to an adsorbent-to-drug ratio of 8:1 at 37 °C. Simulated gastric and intestinal fluid were prepared using pepsin and pancreatin, respectively. For isotherm analysis, paracetamol solutions were tested at charcoal-to-drug ratios ranging from 1:1 to 10:1 using a fixed 20 mg adsorbent dose. Kinetic modeling and the effects of ethanol and flavoring agents were also evaluated. RESULTS: Paracetamol adsorption efficiencies were 87 ± 0.5% and 85 ± 0.8% for modified activated charcoal in simulated gastric and intestinal fluid, respectively. Hospital-grade activated charcoal efficiencies were 47 ± 0.7% and 58 ± 0.6%. Maximum adsorption capacities were 574.93 and 566.71 mg/g for modified activated charcoal and 173.98 and 294.64 mg/g for hospital-grade activated charcoal. Adsorption data fitted the Freundlich isotherm for modified activated charcoal and the Langmuir model for hospital-grade activated charcoal. Exposure to ethanol reduced adsorption by approximately 14% and 32% for modified and hospital-grade activated charcoals, respectively. Flavoring agents reduced adsorption by about 5% and 10% for modified and hospital-grade activated charcoals, respectively. Kinetic analysis indicated a pseudo-second-order model for both materials. DISCUSSION: Modified activated charcoal showed higher paracetamol adsorption efficiency and capacity than hospital-grade activated charcoal under simulated gastric and intestinal conditions, with stable performance in enzyme and flavoring agent environments. CONCLUSION: evaluation are needed to confirm clinical applicability.

Authors

Institutions

Publication Details

Journal
Clinical Toxicology
Published
2026-04-17
DOI
https://doi.org/10.1080/15563650.2026.2649345
Primary Topic
Poisoning and overdose treatments
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative evaluation of ammonium chloride-modified and hospital-grade activated charcoal for paracetamol adsorption under simulated gastric (pepsin) and intestinal (pancreatin) fluid

Mehdi Salari, Forough Riahimanesh, Samad Nazemi, Ahmad Alahabadi
Clinical Toxicology
Poisoning and overdose treatments
article

Comparative evaluation of ammonium chloride-modified and hospital-grade activated charcoal for paracetamol adsorption under simulated gastric (pepsin) and intestinal (pancreatin) fluid

Mehdi Salari, Forough Riahimanesh, Samad Nazemi, Ahmad Alahabadi
article en

Abstract

INTRODUCTION: wood, with hospital-grade activated charcoal in simulated gastric and intestinal fluid. METHODS: Adsorption experiments were conducted using 20 mg of activated charcoal, in a paracetamol solution containing 2.5 mg of paracetamol (50 mg/L in 50 mL), corresponding to an adsorbent-to-drug ratio of 8:1 at 37 °C. Simulated gastric and intestinal fluid were prepared using pepsin and pancreatin, respectively. For isotherm analysis, paracetamol solutions were tested at charcoal-to-drug ratios ranging from 1:1 to 10:1 using a fixed 20 mg adsorbent dose. Kinetic modeling and the effects of ethanol and flavoring agents were also evaluated. RESULTS: Paracetamol adsorption efficiencies were 87 ± 0.5% and 85 ± 0.8% for modified activated charcoal in simulated gastric and intestinal fluid, respectively. Hospital-grade activated charcoal efficiencies were 47 ± 0.7% and 58 ± 0.6%. Maximum adsorption capacities were 574.93 and 566.71 mg/g for modified activated charcoal and 173.98 and 294.64 mg/g for hospital-grade activated charcoal. Adsorption data fitted the Freundlich isotherm for modified activated charcoal and the Langmuir model for hospital-grade activated charcoal. Exposure to ethanol reduced adsorption by approximately 14% and 32% for modified and hospital-grade activated charcoals, respectively. Flavoring agents reduced adsorption by about 5% and 10% for modified and hospital-grade activated charcoals, respectively. Kinetic analysis indicated a pseudo-second-order model for both materials. DISCUSSION: Modified activated charcoal showed higher paracetamol adsorption efficiency and capacity than hospital-grade activated charcoal under simulated gastric and intestinal conditions, with stable performance in enzyme and flavoring agent environments. CONCLUSION: evaluation are needed to confirm clinical applicability.

Clinical Toxicology
Sabzevar University of Medical Sciences (IR)
Sabzevar University of Medical Sciences
Zero hunger
Openalex Percentile: Top 13%
Poisoning and overdose treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.