Comparative Use of Double Bipolar Forceps Versus Ultrasound Energy Device in Transoral Robotic Thyroidectomy

PURPOSE: Transoral robotic thyroidectomy (TORT) offers excellent cosmetic outcomes and safe access to the central neck without a cervical incision. Traditionally, ultrasonic energy devices have been used for dissection and hemostasis, though these instruments are limited by unilateral use, bulkiness, and greater thermal spread. Double bipolar forceps, when used bilaterally, provide enhanced precision, full articulation, smoke reduction, and integration with intraoperative nerve monitoring, thereby enabling efficient bimanual dissection and continuous traction without frequent instrument exchanges. METHOD: This video illustrates the operative techniques of both ultrasonic energy devices and double bipolar forceps in TORT, highlighting their technical nuances and practical advantages. FINDING: In a retrospective study of 1726 TORT cases performed by a single surgeon, operative times were significantly shorter in the double bipolar forceps group compared with the ultrasonic device group (lobectomy: 131.7 ± 25.1 min vs. 174.7 ± 35.2 min, p < 0.001; total thyroidectomy: 185.6 ± 44.7 min vs. 217.4 ± 65.8 min, p < 0.001), while complication rates were comparable. CONCLUSION: Together, the video and clinical data underscore the value of bipolar forceps as an effective alternative to conventional energy devices in robotic thyroid surgery.

Authors

Institutions

Publication Details

Journal
Head & Neck
Published
2026-04-16
DOI
https://doi.org/10.1002/hed.70280
Primary Topic
Thyroid and Parathyroid Surgery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Use of Double Bipolar Forceps Versus Ultrasound Energy Device in Transoral Robotic Thyroidectomy

Young Jun Chai, Hoon Yub Kim, Dawon Park, Moon Young Oh et al.
Head & Neck
Thyroid and Parathyroid Surgery
article

Comparative Use of Double Bipolar Forceps Versus Ultrasound Energy Device in Transoral Robotic Thyroidectomy

Young Jun Chai, Hoon Yub Kim, Dawon Park, Moon Young Oh, Mustafa AlMadan, Kwangsoon Kim
article en

Abstract

PURPOSE: Transoral robotic thyroidectomy (TORT) offers excellent cosmetic outcomes and safe access to the central neck without a cervical incision. Traditionally, ultrasonic energy devices have been used for dissection and hemostasis, though these instruments are limited by unilateral use, bulkiness, and greater thermal spread. Double bipolar forceps, when used bilaterally, provide enhanced precision, full articulation, smoke reduction, and integration with intraoperative nerve monitoring, thereby enabling efficient bimanual dissection and continuous traction without frequent instrument exchanges. METHOD: This video illustrates the operative techniques of both ultrasonic energy devices and double bipolar forceps in TORT, highlighting their technical nuances and practical advantages. FINDING: In a retrospective study of 1726 TORT cases performed by a single surgeon, operative times were significantly shorter in the double bipolar forceps group compared with the ultrasonic device group (lobectomy: 131.7 ± 25.1 min vs. 174.7 ± 35.2 min, p < 0.001; total thyroidectomy: 185.6 ± 44.7 min vs. 217.4 ± 65.8 min, p < 0.001), while complication rates were comparable. CONCLUSION: Together, the video and clinical data underscore the value of bipolar forceps as an effective alternative to conventional energy devices in robotic thyroid surgery.

Head & Neck
New Generation University College (ET), Seoul National University Hospital (KR), SNUH SMG-SNU Boramae Medical Center (KR), Qatif Central Hospital (SA), Korea University (JP), Catholic University of Korea (KR)
Affordable and clean energy
Openalex Percentile: Top 14%
Thyroid and Parathyroid Surgery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparative Use of Double Bipolar Forceps Versus Ultrasound Energy Device in Transoral Robotic Thyroidectomy — Young Jun Chai, Hoon Yub Kim, et al. · Head & Neck (2026) | TGRS Research Map | TGRS