Reproducible System Innovation in DICOM Mammography Processing with Pixel-Monotonic Dynamic Range Control

This paper presents a reproducible system innovation for processing Digital Imaging and Communications in Medicine (DICOM) mammography images based on pixel-monotonic dynamic range management and engineering-verifiable intensity transformations. Standard DICOM conversion schemes to 8-bit representation often result in irreversible luminance-range compression, locality-dependent contrast distortions, and reduced robustness of deep learning models. The proposed framework preserves the physical consistency of the Modality LUT and photometric polarity, performs breast-aware robust Winsor normalization, and applies strictly monotonic global tone mapping while preserving the 16-bit depth of the training data. System validation was performed using architecture-independent metrics. Compared to standard processing, the median value of normalized mutual information increased from 0.878 to 0.892, the effective number of bits increased from 7.88 to 10.11 (+2.25), the representation entropy increased by 1.42 bits, and the clipping rate was reduced to almost zero. Experiments with the Faster R-CNN detector showed stable or improved calcification localization at Intersection over Union (IoU) ≥ 0.5 under controlled augmentation conditions. The results confirm that pixel-monotonic dynamic range control provides a reproducible, engineering-verifiable basis for AI-based mammography analysis within the evaluated dataset and experimental setting.

Authors

Institutions

Publication Details

Journal
Technologies
Published
2026-04-17
DOI
https://doi.org/10.3390/technologies14040236
Primary Topic
Digital Radiography and Breast Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reproducible System Innovation in DICOM Mammography Processing with Pixel-Monotonic Dynamic Range Control

Aisulu Ismailova, Ainur Shekerbek, Gulzira Abdikerimova, Kuanysh Kadirkulov et al.
Technologies
Digital Radiography and Breast Imaging
article

Reproducible System Innovation in DICOM Mammography Processing with Pixel-Monotonic Dynamic Range Control

Aisulu Ismailova, Ainur Shekerbek, Gulzira Abdikerimova, Kuanysh Kadirkulov, Moldir Yessenova, Balkiya Zhylanbaeva, Gulbarshin Rakhimbayeva, Zhanat Manbetova, Ainur Orynbayeva
article en

Abstract

This paper presents a reproducible system innovation for processing Digital Imaging and Communications in Medicine (DICOM) mammography images based on pixel-monotonic dynamic range management and engineering-verifiable intensity transformations. Standard DICOM conversion schemes to 8-bit representation often result in irreversible luminance-range compression, locality-dependent contrast distortions, and reduced robustness of deep learning models. The proposed framework preserves the physical consistency of the Modality LUT and photometric polarity, performs breast-aware robust Winsor normalization, and applies strictly monotonic global tone mapping while preserving the 16-bit depth of the training data. System validation was performed using architecture-independent metrics. Compared to standard processing, the median value of normalized mutual information increased from 0.878 to 0.892, the effective number of bits increased from 7.88 to 10.11 (+2.25), the representation entropy increased by 1.42 bits, and the clipping rate was reduced to almost zero. Experiments with the Faster R-CNN detector showed stable or improved calcification localization at Intersection over Union (IoU) ≥ 0.5 under controlled augmentation conditions. The results confirm that pixel-monotonic dynamic range control provides a reproducible, engineering-verifiable basis for AI-based mammography analysis within the evaluated dataset and experimental setting.

TechnologiesVol. 14(4)
L. N. Gumilyov Eurasian National University (KZ), Kazakh National Medical University (KZ), S.Seifullin Kazakh Agro Technical University (KZ), Astana Medical University (KZ)
Industry, innovation and infrastructure
Openalex Percentile: Top 21%
Digital Radiography and Breast Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.