Disinfection of poultry processing wastewater using advanced oxidation processes

CFU/mL and analyzed using linear mixed-effects model on R software (p ≤ 0.05) with a limit of detection of 1 CFU/mL. Across all wastewater types and reactor scales, PEC treatment at 70 V and 100 V achieved substantial reductions in AC, reducing initial loads of 5.4 - 6.2 log CFU/mL to 2.0 - 2.9 log CFU/mL within 300 minutes. Specifically, treatments at 100 V reduced AC to below the regulatory threshold of 500 CFU/mL (2.70 log CFU/mL) for wastewater reuse. EB, CC, and E. coli were completely inactivated, with faster disinfection generally observed at 100 V (120-180 minutes) compared to 70 V (180-210 minutes). Although differences between pathogen reductions were insignificant between 70 V and 100 V (p> 0.05), disinfection at 100 V showed a trend of quicker and greater microbial reduction across all microorganisms tested. Furthermore, Campylobacter and Salmonella were consistently eliminated within 150 minutes across all treatments. Overall, these findings demonstrate PEC as a viable, sustainable disinfection strategy which effectively reduced microorganisms including Campylobacter and Salmonella in processing wastewater, supporting safe reuse while reducing environmental impact.

Authors

Institutions

Publication Details

Journal
Poultry Science
Published
2026-04-17
DOI
https://doi.org/10.1016/j.psj.2026.106954
Primary Topic
Listeria monocytogenes in Food Safety
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Disinfection of poultry processing wastewater using advanced oxidation processes

Tomi Obe, N. N. Barashkov, Mark Carlson, Seth Adesope et al.
Poultry Science
Listeria monocytogenes in Food Safety
article

Disinfection of poultry processing wastewater using advanced oxidation processes

Tomi Obe, N. N. Barashkov, Mark Carlson, Seth Adesope, Casey Owens
article en

Abstract

CFU/mL and analyzed using linear mixed-effects model on R software (p ≤ 0.05) with a limit of detection of 1 CFU/mL. Across all wastewater types and reactor scales, PEC treatment at 70 V and 100 V achieved substantial reductions in AC, reducing initial loads of 5.4 - 6.2 log CFU/mL to 2.0 - 2.9 log CFU/mL within 300 minutes. Specifically, treatments at 100 V reduced AC to below the regulatory threshold of 500 CFU/mL (2.70 log CFU/mL) for wastewater reuse. EB, CC, and E. coli were completely inactivated, with faster disinfection generally observed at 100 V (120-180 minutes) compared to 70 V (180-210 minutes). Although differences between pathogen reductions were insignificant between 70 V and 100 V (p> 0.05), disinfection at 100 V showed a trend of quicker and greater microbial reduction across all microorganisms tested. Furthermore, Campylobacter and Salmonella were consistently eliminated within 150 minutes across all treatments. Overall, these findings demonstrate PEC as a viable, sustainable disinfection strategy which effectively reduced microorganisms including Campylobacter and Salmonella in processing wastewater, supporting safe reuse while reducing environmental impact.

Poultry ScienceVol. 105(7)
University of Arkansas System (US), Tracer Technologies (United States) (US), University of Arkansas at Fayetteville (US)
National Institute of Food and Agriculture
Clean water and sanitation
Openalex Percentile: Top 22%
Listeria monocytogenes in Food Safety
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.