Infant and toddler’s preoperative chest imaging on photon-counting detector CT: a paired-sample comparison with energy-integrating detector CT on image quality and radiation dose

Photon-counting CT (PCCT) may improve dose efficiency compared with energy-integrating detector CT (EID-CT), but evidence remains limited in very young children undergoing non-contrast preoperative chest CT under real-world clinical protocols. To provide a size-aware matched comparison of radiation dose and image quality between PCCT and EID-CT in infants and toddlers (≤ 36 months) undergoing non-contrast preoperative chest CT, and to examine whether the main findings remained directionally consistent across prespecified strata of age, BMI, and water-equivalent diameter (DW). In this single-center matched cohort study, a prospective PCCT cohort and a retrospective EID-CT cohort were propensity score–matched 1:1 (49 pairs). Dose metrics (CTDIvol, DLP, SSDE) and objective and subjective image quality were evaluated, with subgroup analyses stratified by age (< 12 vs. ≥ 12 months), BMI tertiles, and DW tertiles. The PCCT group showed significantly lower radiation dose metrics (CTDIvol, DLP, and SSDE) compared to the EID-CT group (P < 0.001). In terms of objective image quality, PCCT significantly reduced image noise in all lung lobes and consistently demonstrated higher signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) (all P < 0.001). Subjective image quality assessments showed no significant difference between PCCT and EID-CT (P > 0.05). Across prespecified age, BMI, and DW strata, PCCT remained associated with lower dose metrics and favorable objective image-quality trends, although these subgroup findings should be interpreted as exploratory. In this matched cohort of infants and toddlers undergoing non-contrast preoperative chest CT, PCCT was associated with substantially lower radiation dose and improved objective image quality compared with EID-CT, and no statistically significant difference was detected in subjective image quality scores between PCCT and EID-CT.

Authors

Institutions

Publication Details

Journal
BMC Medical Imaging
Published
2026-04-16
DOI
https://doi.org/10.1186/s12880-026-02339-7
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Infant and toddler’s preoperative chest imaging on photon-counting detector CT: a paired-sample comparison with energy-integrating detector CT on image quality and radiation dose

Wei‐Hui Xie, Shifeng Xu, Yi-Xiang Wang, Ruo‐Yang Shi et al.
BMC Medical Imaging
Advanced X-ray and CT Imaging
article

Infant and toddler’s preoperative chest imaging on photon-counting detector CT: a paired-sample comparison with energy-integrating detector CT on image quality and radiation dose

Wei‐Hui Xie, Shifeng Xu, Yi-Xiang Wang, Ruo‐Yang Shi, Lian-Ming Wu, Tang-Xu Sun, Wei-Dong Qiao, Wei Zhou, Xiang-Yu Liu
article en

Abstract

Photon-counting CT (PCCT) may improve dose efficiency compared with energy-integrating detector CT (EID-CT), but evidence remains limited in very young children undergoing non-contrast preoperative chest CT under real-world clinical protocols. To provide a size-aware matched comparison of radiation dose and image quality between PCCT and EID-CT in infants and toddlers (≤ 36 months) undergoing non-contrast preoperative chest CT, and to examine whether the main findings remained directionally consistent across prespecified strata of age, BMI, and water-equivalent diameter (DW). In this single-center matched cohort study, a prospective PCCT cohort and a retrospective EID-CT cohort were propensity score–matched 1:1 (49 pairs). Dose metrics (CTDIvol, DLP, SSDE) and objective and subjective image quality were evaluated, with subgroup analyses stratified by age (< 12 vs. ≥ 12 months), BMI tertiles, and DW tertiles. The PCCT group showed significantly lower radiation dose metrics (CTDIvol, DLP, and SSDE) compared to the EID-CT group (P < 0.001). In terms of objective image quality, PCCT significantly reduced image noise in all lung lobes and consistently demonstrated higher signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) (all P < 0.001). Subjective image quality assessments showed no significant difference between PCCT and EID-CT (P > 0.05). Across prespecified age, BMI, and DW strata, PCCT remained associated with lower dose metrics and favorable objective image-quality trends, although these subgroup findings should be interpreted as exploratory. In this matched cohort of infants and toddlers undergoing non-contrast preoperative chest CT, PCCT was associated with substantially lower radiation dose and improved objective image quality compared with EID-CT, and no statistically significant difference was detected in subjective image quality scores between PCCT and EID-CT.

BMC Medical Imaging
Renji Hospital (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 8%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.