Anatomy-based individualised trocar placement in robotic pancreatic surgery: challenging the universal approach

Robotic pancreatic surgery has advanced considerably in recent years; however, morbidity and mortality remain significant. Improving outcomes requires standardised procedures with optimised perioperative settings. Proper positioning of robotic trocars plays a key role in enabling safe and effective surgical performance. This study evaluates the impact of anthropometric differences on trocar placement in robotic pancreatic surgery and assesses the feasibility of a universal trocar placement strategy. A retrospective analysis of 103 consecutive contrast-enhanced arterial-phase computed tomography scans was performed. Key distances between the target anatomy and surface landmarks, including the umbilicus and xiphoid process, were measured. The origin of the gastroduodenal artery was selected as the target anatomy for pancreaticoduodenectomy, while the origin of the celiac trunk served as the target anatomy for distal pancreatectomy. The analysis demonstrated that the widely adopted universal periumbilical trocar placement was unsuitable for a substantial proportion of patients. The target anatomy lay outside the recommended range (10–20 cm) in 24% of robotic pancreaticoduodenectomy cases and in 9% of robotic distal pancreatectomy cases. Accordingly, we propose a simple method to optimise patient-tailored yet standardised trocar placement in robotic pancreatic procedures. Conventional vs. Novel Techniques: Robotic pancreatic surgery has emerged as an alternative to open and laparoscopic approaches. A universal approach to trocar placement is widely adopted; however, considerable inter-individual anatomical variability challenges its effectiveness. Modifications and Innovations: This study evaluates an individualised trocar placement strategy tailored to patient-specific anatomical variation. Target anatomy corresponds to the origin of the gastroduodenal artery for pancreaticoduodenectomy and the origin of the celiac trunk for distal pancreatectomy. Preoperative contrast-enhanced computed tomography scans were used for assessment. The tailored approach incorporates measurements between the umbilicus, xiphoid process, and the target anatomy, thereby optimising robotic trocar positioning for each patient. Implications and Recommendations: A standardised trocar placement approach may not be optimal for all robotic pancreatic procedures because of anthropometric differences. An individualised strategy may improve surgical efficiency, minimise instrument collisions, and potentially enhance perioperative outcomes.

Authors

Institutions

Publication Details

Journal
Journal of Robotic Surgery
Published
2026-04-16
DOI
https://doi.org/10.1007/s11701-026-03376-8
Primary Topic
Minimally Invasive Surgical Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Anatomy-based individualised trocar placement in robotic pancreatic surgery: challenging the universal approach

Štěpán-Ota Schütz, David Kachlík, Radek Pohnán, Pavel Záruba et al.
Journal of Robotic Surgery
Minimally Invasive Surgical Techniques
article

Anatomy-based individualised trocar placement in robotic pancreatic surgery: challenging the universal approach

Štěpán-Ota Schütz, David Kachlík, Radek Pohnán, Pavel Záruba, Eliška Kšírová, Kristýna Pončáková, Michael Rousek
article en

Abstract

Robotic pancreatic surgery has advanced considerably in recent years; however, morbidity and mortality remain significant. Improving outcomes requires standardised procedures with optimised perioperative settings. Proper positioning of robotic trocars plays a key role in enabling safe and effective surgical performance. This study evaluates the impact of anthropometric differences on trocar placement in robotic pancreatic surgery and assesses the feasibility of a universal trocar placement strategy. A retrospective analysis of 103 consecutive contrast-enhanced arterial-phase computed tomography scans was performed. Key distances between the target anatomy and surface landmarks, including the umbilicus and xiphoid process, were measured. The origin of the gastroduodenal artery was selected as the target anatomy for pancreaticoduodenectomy, while the origin of the celiac trunk served as the target anatomy for distal pancreatectomy. The analysis demonstrated that the widely adopted universal periumbilical trocar placement was unsuitable for a substantial proportion of patients. The target anatomy lay outside the recommended range (10–20 cm) in 24% of robotic pancreaticoduodenectomy cases and in 9% of robotic distal pancreatectomy cases. Accordingly, we propose a simple method to optimise patient-tailored yet standardised trocar placement in robotic pancreatic procedures. Conventional vs. Novel Techniques: Robotic pancreatic surgery has emerged as an alternative to open and laparoscopic approaches. A universal approach to trocar placement is widely adopted; however, considerable inter-individual anatomical variability challenges its effectiveness. Modifications and Innovations: This study evaluates an individualised trocar placement strategy tailored to patient-specific anatomical variation. Target anatomy corresponds to the origin of the gastroduodenal artery for pancreaticoduodenectomy and the origin of the celiac trunk for distal pancreatectomy. Preoperative contrast-enhanced computed tomography scans were used for assessment. The tailored approach incorporates measurements between the umbilicus, xiphoid process, and the target anatomy, thereby optimising robotic trocar positioning for each patient. Implications and Recommendations: A standardised trocar placement approach may not be optimal for all robotic pancreatic procedures because of anthropometric differences. An individualised strategy may improve surgical efficiency, minimise instrument collisions, and potentially enhance perioperative outcomes.

Journal of Robotic SurgeryVol. 20(1)
Charles University (CZ), Military University Hospital Prague (CZ)
Ministerstvo Obrany České Republiky
Good health and well-being
Openalex Percentile: Top 11%
Minimally Invasive Surgical Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.