Accuracy Assessment of Planned Versus Actual Trajectories in Robotic-Assisted Spine Surgery Utilizing Perioperative O-Arm CT Scans

Study design A prospective cohort study. Objectives To find the deviations in entry point, axial angulation, and sagittal angulation between the planned trajectories versus the achieved trajectories in Mazor-X robotic spine surgery. Methods This study was conducted from December 2023 to June 2025, including 250 patients undergoing robotic-assisted pedicle screw fixation. Planned and actual screw trajectories were compared using perioperative O-arm CT scans. Results A total of 1170 screws were inserted (96 thoracic, 1074 lumbar). Mean entry deviation was 2.27 ± 1.5 mm, axial angular deviation 3.7° ± 3.7°, and sagittal deviation 3.4° ± 3.2°. A clinically acceptable placement rate of 99.7% was achieved, with only four breaches requiring revision. Operative time and screw insertion time decreased with experience, reflecting a short learning curve. Conclusion Robotic guidance using the Mazor X Stealth Edition (Medtronic, 2018, Memphis, Tennessee) ensures highly accurate and safe pedicle screw placement in spine surgery.

Authors

Publication Details

Journal
Cureus
Published
2026-04-16
DOI
https://doi.org/10.7759/cureus.107146
Primary Topic
Spinal Fractures and Fixation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy Assessment of Planned Versus Actual Trajectories in Robotic-Assisted Spine Surgery Utilizing Perioperative O-Arm CT Scans

Mikeson Panthackel, Yogenkumar Adodariya, Amritesh Singh, Saurabh S Kulkarni et al.
Cureus
Spinal Fractures and Fixation Techniques
article

Accuracy Assessment of Planned Versus Actual Trajectories in Robotic-Assisted Spine Surgery Utilizing Perioperative O-Arm CT Scans

Mikeson Panthackel, Yogenkumar Adodariya, Amritesh Singh, Saurabh S Kulkarni, Bharatkumar R Dave, Ravi Ranjan Rai, Shivanand C Mayi, Arjit Vashishtha, Ajay Krishnan, Mirant B Dave
article en

Abstract

Study design A prospective cohort study. Objectives To find the deviations in entry point, axial angulation, and sagittal angulation between the planned trajectories versus the achieved trajectories in Mazor-X robotic spine surgery. Methods This study was conducted from December 2023 to June 2025, including 250 patients undergoing robotic-assisted pedicle screw fixation. Planned and actual screw trajectories were compared using perioperative O-arm CT scans. Results A total of 1170 screws were inserted (96 thoracic, 1074 lumbar). Mean entry deviation was 2.27 ± 1.5 mm, axial angular deviation 3.7° ± 3.7°, and sagittal deviation 3.4° ± 3.2°. A clinically acceptable placement rate of 99.7% was achieved, with only four breaches requiring revision. Operative time and screw insertion time decreased with experience, reflecting a short learning curve. Conclusion Robotic guidance using the Mazor X Stealth Edition (Medtronic, 2018, Memphis, Tennessee) ensures highly accurate and safe pedicle screw placement in spine surgery.

Cureus
Openalex Percentile: Top 23%
Spinal Fractures and Fixation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.