Long-Term Intraocular Pressure-Lowering and Antifibrotic Effects of a Biodegradable HA-Mg Glaucoma Drainage Implant in a Chronic Glaucoma Rabbit Model

Purpose: The purpose of this study was to evaluate the long-term intraocular pressure (IOP)-lowering efficacy, antifibrotic activity, and outflow patency of a hydroxyapatite-coated degradable magnesium (HA-Mg) glaucoma drainage implant in a chronic glaucoma rabbit model. Methods: Chronic glaucoma was induced by anterior chamber injection of a magnetic bead suspension, and glaucomatous damage was confirmed by retinal thinning and optic nerve injury. In a separate cohort, glaucomatous eyes were randomized to trabeculectomy (TL), sham surgery, or HA-Mg implantation (n = 6/group) and followed for 6 months. IOP and corneal diameter were monitored longitudinally, aqueous outflow was evaluated using intracameral trypan blue, and filtration tissues were examined histologically. Results: Modeled eyes maintained IOP at approximately 30 millimeters of mercury (mm Hg) for 6 weeks, accompanied by retinal thinning and optic nerve damage. After treatment, IOP in the HA-Mg group decreased below 21 mm Hg and remained significantly lower than in the sham and TL groups, in which IOP remained elevated or rebounded. Only HA-Mg-implanted eyes showed recovery of corneal diameter to baseline at 6 months. Trypan blue testing demonstrated persistent subconjunctival drainage in the HA-Mg group, and histology revealed reduced fibroblast proliferation, decreased collagen deposition, and preservation of a clear filtration pathway. Conclusions: The degradable HA-Mg implant was well tolerated, provided sustained IOP reduction, and maintained outflow patency while attenuating postoperative fibrosis, supporting its potential for clinical translation in glaucoma filtration surgery. Translational Relevance: A biodegradable HA-Mg drainage implant that sustains outflow and limits fibrosis may offer a safer and more durable alternative to permanent subconjunctival drainage devices.

Authors

Institutions

Publication Details

Journal
Translational Vision Science & Technology
Published
2026-04-16
DOI
https://doi.org/10.1167/tvst.15.4.16
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Long-Term Intraocular Pressure-Lowering and Antifibrotic Effects of a Biodegradable HA-Mg Glaucoma Drainage Implant in a Chronic Glaucoma Rabbit Model

X Li, Qi Gou, Hui Li, Minghe Xiao et al.
Translational Vision Science & Technology
Glaucoma and retinal disorders
article

Long-Term Intraocular Pressure-Lowering and Antifibrotic Effects of a Biodegradable HA-Mg Glaucoma Drainage Implant in a Chronic Glaucoma Rabbit Model

X Li, Qi Gou, Hui Li, Minghe Xiao, Lingling Li, Fangfang Chen, Lin Xie, Yong Wang, Wangdu Luo, Yi Chen
article en

Abstract

Purpose: The purpose of this study was to evaluate the long-term intraocular pressure (IOP)-lowering efficacy, antifibrotic activity, and outflow patency of a hydroxyapatite-coated degradable magnesium (HA-Mg) glaucoma drainage implant in a chronic glaucoma rabbit model. Methods: Chronic glaucoma was induced by anterior chamber injection of a magnetic bead suspension, and glaucomatous damage was confirmed by retinal thinning and optic nerve injury. In a separate cohort, glaucomatous eyes were randomized to trabeculectomy (TL), sham surgery, or HA-Mg implantation (n = 6/group) and followed for 6 months. IOP and corneal diameter were monitored longitudinally, aqueous outflow was evaluated using intracameral trypan blue, and filtration tissues were examined histologically. Results: Modeled eyes maintained IOP at approximately 30 millimeters of mercury (mm Hg) for 6 weeks, accompanied by retinal thinning and optic nerve damage. After treatment, IOP in the HA-Mg group decreased below 21 mm Hg and remained significantly lower than in the sham and TL groups, in which IOP remained elevated or rebounded. Only HA-Mg-implanted eyes showed recovery of corneal diameter to baseline at 6 months. Trypan blue testing demonstrated persistent subconjunctival drainage in the HA-Mg group, and histology revealed reduced fibroblast proliferation, decreased collagen deposition, and preservation of a clear filtration pathway. Conclusions: The degradable HA-Mg implant was well tolerated, provided sustained IOP reduction, and maintained outflow patency while attenuating postoperative fibrosis, supporting its potential for clinical translation in glaucoma filtration surgery. Translational Relevance: A biodegradable HA-Mg drainage implant that sustains outflow and limits fibrosis may offer a safer and more durable alternative to permanent subconjunctival drainage devices.

Translational Vision Science & TechnologyVol. 15(4)
Chongqing University (CN), Sichuan Agricultural University (CN), Third People 's Hospital of Chongqing (CN), Chongqing Medical University (CN)
Life in Land
Openalex Percentile: Top 9%
Glaucoma and retinal disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.