GPT-4o for Automated Determination of Follow-up Examinations Based on Radiology Reports from Clinical Routine
Follow-up imaging recommendations vary across radiologists despite established guidelines. We evaluated whether a large language model (GPT-4o) can standardize follow-up timing and modality selection from routine radiology reports. In this retrospective, two-center study, 100 CT/MRI cases (25 each: head/neck, liver, lung, pancreas) were randomly sampled. GPT-4o and two human readers (R1, resident; R2, board-certified) generated follow-up recommendations from report text. Expert consensus, blinded to rater, assessed completeness, appropriateness of imaging modality, timing accuracy, and global follow up quality on a 5-point scale, with 5 being the highest score. Median global quality was 4 (2–5) for GPT-4o, 4 (1–5) for R1, and 4 (1–5) for R2; GPT-4o exceeded R1 (p < 0.01) and did not differ from 2 (p = 0.06). Relative treatment effect showed a reader effect (GPT4o 0.56 vs. R1 0.43 vs. R2 0.51; p < 0.01) and no center effect (0.50 vs. 0.50; p = 0.91). Correctness of follow-up timing was 96% (96/100) for GPT-4o, 75% (75/100) for R1, and 90% (90/100) for R2 (p < 0.001 for GPT-4o vs. R1). Completeness of follow-up was 92% (92/100) for GPT-4o, 91% (91/100) for R1, and 80% (80/100) for R2 (p = 0.014 for GPT-4o vs. Reader 2). No significant differences were observed regarding appropriateness of imaging modality. GPT-4o generated follow-up recommendations with overall quality comparable to an experienced radiologist and superior to a trainee, with high completeness and generally appropriate follow up timing and modality, supporting its role as decision support for standardized, guideline-aligned follow-up.
Authors
- Thorsten Persigehl (ORCID: https://orcid.org/0000-0001-5928-4405)
- Tobias Jorg (ORCID: https://orcid.org/0000-0002-1027-6700)
- Lenhard Pennig (ORCID: https://orcid.org/0000-0002-6606-9313)
- Andra-Iza Iuga (ORCID: https://orcid.org/0000-0002-3694-0235)
- Christian Nelles (ORCID: https://orcid.org/0000-0002-7351-7516)
- Thomas Schömig (ORCID: https://orcid.org/0009-0001-7560-4285)
- Thomas Dratsch (ORCID: https://orcid.org/0000-0003-4014-7763)
- David Zopfs (ORCID: https://orcid.org/0000-0001-9978-7453)
- Nedim Beste
- Robert Terzis
- Kenan Kaya
- Lukas Müller
- Carsten Gietzen
- Jan Paul Janssen
- David Maintz
- Jonathan Kottlors
Institutions
- University of Cologne (DE)
- Johannes Gutenberg University Mainz (DE)
- University Medical Center of the Johannes Gutenberg University Mainz (DE)
- University Hospital Cologne (DE)
Publication Details
- Journal
- Scientific Reports
- Published
- 2026-04-16
- DOI
- https://doi.org/10.1038/s41598-026-40317-9
- Primary Topic
- Radiology practices and education
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Universität zu Köln
- Universitätsklinikum Köln