Strain ratio elastography for predicting malignant breast lesion: a new grading classification

Introduction: Strain ratio elastography (SRE) lacks a standard classification to establish a cutoff value for predicting malignant breast lesions. This study proposes a new three-grade classification based on SRE cutoff values using the LOGIQ E9 GE Healthcare system and evaluates its diagnostic performance in predicting breast lesion malignancy. Material and Methods: This retrospective cross-sectional study included women with Breast Imaging Reporting and Data System (BI-RADS) breast lesions categories 4 or 5. All lesions were evaluated with conventional ultrasound (US) and strain elastography (SE) with a GE Healthcare LOGIQ E9 system. The semiquantitative three-grade classification cutoff values defined arbitrarily based on SRE were grade 1 (0-1.9, soft pattern), grade 2 (2.0-3.9, intermediate pattern), and grade 3 (4.0-6, hard pattern). Histopathologic diagnosis was the gold standard. Receiver operating characteristic (ROC) analysis was used to compare SRE cutoffs ≥ 2 and ≥ 4. Results: Of 173 breast lesions, 73 (42.0%) were benign, and 100 (58.0%) were malignant. Benign lesions were primarily grade 1 (42.0%) and 2 (33.0%), while 71% of malignant lesions were grade 3 (p < 0.001). The median SRE cutoff value was higher in malignant (5.2) than in benign lesions (2.4) (p < 0.001). A cutoff ≥ 2 showed high sensitivity (93.0%) and low specificity (42.4%) for predicting malignant breast lesions, whereas a value ≥ 4 showed a sensitivity of 71.0%, a specificity of 75.3%, and an accuracy of 72.8%. Conclusion: The proposed SRE three-grade classification demonstrated that a grade 3 hard pattern (cutoff ≥ 4) as defined by the GE Healthcare LOGIQ E9 system achieved good diagnostic performance for predicting malignant BI-RADS 4 or 5 breast lesions; it is useful for characterizing breast lesions.

Authors

Publication Details

Journal
Journal of the Mexican Federation of Radiology and Imaging
Published
2026-04-16
DOI
https://doi.org/10.24875/jmexfri.m26000123
Primary Topic
Ultrasound Imaging and Elastography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Strain ratio elastography for predicting malignant breast lesion: a new grading classification

David F. Perez-Montemayor, Karla G. Garcia-Alvarez, Roberto A. Sandoval-Villanueva, Karla A. Lopez-Rodríguez
Journal of the Mexican Federation of Radiology and Imaging
Ultrasound Imaging and Elastography
article

Strain ratio elastography for predicting malignant breast lesion: a new grading classification

David F. Perez-Montemayor, Karla G. Garcia-Alvarez, Roberto A. Sandoval-Villanueva, Karla A. Lopez-Rodríguez
article en

Abstract

Introduction: Strain ratio elastography (SRE) lacks a standard classification to establish a cutoff value for predicting malignant breast lesions. This study proposes a new three-grade classification based on SRE cutoff values using the LOGIQ E9 GE Healthcare system and evaluates its diagnostic performance in predicting breast lesion malignancy. Material and Methods: This retrospective cross-sectional study included women with Breast Imaging Reporting and Data System (BI-RADS) breast lesions categories 4 or 5. All lesions were evaluated with conventional ultrasound (US) and strain elastography (SE) with a GE Healthcare LOGIQ E9 system. The semiquantitative three-grade classification cutoff values defined arbitrarily based on SRE were grade 1 (0-1.9, soft pattern), grade 2 (2.0-3.9, intermediate pattern), and grade 3 (4.0-6, hard pattern). Histopathologic diagnosis was the gold standard. Receiver operating characteristic (ROC) analysis was used to compare SRE cutoffs ≥ 2 and ≥ 4. Results: Of 173 breast lesions, 73 (42.0%) were benign, and 100 (58.0%) were malignant. Benign lesions were primarily grade 1 (42.0%) and 2 (33.0%), while 71% of malignant lesions were grade 3 (p < 0.001). The median SRE cutoff value was higher in malignant (5.2) than in benign lesions (2.4) (p < 0.001). A cutoff ≥ 2 showed high sensitivity (93.0%) and low specificity (42.4%) for predicting malignant breast lesions, whereas a value ≥ 4 showed a sensitivity of 71.0%, a specificity of 75.3%, and an accuracy of 72.8%. Conclusion: The proposed SRE three-grade classification demonstrated that a grade 3 hard pattern (cutoff ≥ 4) as defined by the GE Healthcare LOGIQ E9 system achieved good diagnostic performance for predicting malignant BI-RADS 4 or 5 breast lesions; it is useful for characterizing breast lesions.

Journal of the Mexican Federation of Radiology and ImagingVol. 5(1)
Openalex Percentile: Top 19%
Ultrasound Imaging and Elastography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.