AIMS: This study evaluated the feasibility, acceptability, and clinical effectiveness of a home-based body water monitoring and preemptive management system using bioelectrical impedance analysis (BIA) in patients with heart failure (HF). METHODS: In this multicenter, open-label, randomized controlled trial, 40 HF patients receiving loop diuretics were assigned to standard care or a home BIA group using a home-based BIA device with a linked application providing weekly feedback and guidance on diuretic management. Feasibility outcomes included study completion, adherence, usability and acceptability scores, and adverse events over 12 weeks. Effectiveness outcomes included changes in NT-proBNP, edema index, New York Heart Association (NYHA) functional class, HF hospitalization, and all-cause mortality. RESULTS: 39 patients were included in the final analysis after exclusion of one patient lost to follow-up in the control group. Patients in the control group were older than those in the home BIA group (70.4 ± 8.3 vs. 57.2 ± 13.5; P = 0.003), and baseline NT-proBNP levels were higher (2737.1 ± 3817.1 vs. 1357.7 ± 2196.8 pg/mL; P = 0.013), while other baseline characteristics were comparable. In the home BIA group, the completion rate was 100.0% and adherence to BIA measurements was 82.5%. Acute kidney injury occurred in one patient (5.0%), with no discontinuations due to adverse events. Usability and acceptability were high (4.21 ± 0.59; 3.90 ± 0.53, respectively) on a 5-point Likert scale. There were no significant differences in changes in NT-proBNP or edema index during follow-up between groups. Worsening NYHA class occurred less frequently in the home BIA group (10.0% vs. 31.6%; P = 0.095). Changes in the edema index correlated with changes in NT-proBNP (r = 0.544; P = 0.002), whereas changes in body weight did not (r = 0.237; P = 0.147). No HF hospitalizations or deaths occurred. CONCLUSIONS: Home-based BIA monitoring with preemptive management is feasible, acceptable, and safe for patients with HF.

Authors

Institutions

Publication Details

Journal
ESC Heart Failure
Published
2026-04-13
DOI
https://doi.org/10.1093/eschf/xvag106
Primary Topic
Body Composition Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Home-based body water monitoring and management system for heart failure patients using bioelectrical impedance analysis

Chi Young Shim, J. O. Na, Jah Yeon Choi, Min Gyu Kong et al.
ESC Heart Failure
Body Composition Measurement Techniques
article

Home-based body water monitoring and management system for heart failure patients using bioelectrical impedance analysis

Chi Young Shim, J. O. Na, Jah Yeon Choi, Min Gyu Kong, Inki Moon, Hwanseok Yong, Seong-Mi Park, Jon Suh
article en

Abstract

AIMS: This study evaluated the feasibility, acceptability, and clinical effectiveness of a home-based body water monitoring and preemptive management system using bioelectrical impedance analysis (BIA) in patients with heart failure (HF). METHODS: In this multicenter, open-label, randomized controlled trial, 40 HF patients receiving loop diuretics were assigned to standard care or a home BIA group using a home-based BIA device with a linked application providing weekly feedback and guidance on diuretic management. Feasibility outcomes included study completion, adherence, usability and acceptability scores, and adverse events over 12 weeks. Effectiveness outcomes included changes in NT-proBNP, edema index, New York Heart Association (NYHA) functional class, HF hospitalization, and all-cause mortality. RESULTS: 39 patients were included in the final analysis after exclusion of one patient lost to follow-up in the control group. Patients in the control group were older than those in the home BIA group (70.4 ± 8.3 vs. 57.2 ± 13.5; P = 0.003), and baseline NT-proBNP levels were higher (2737.1 ± 3817.1 vs. 1357.7 ± 2196.8 pg/mL; P = 0.013), while other baseline characteristics were comparable. In the home BIA group, the completion rate was 100.0% and adherence to BIA measurements was 82.5%. Acute kidney injury occurred in one patient (5.0%), with no discontinuations due to adverse events. Usability and acceptability were high (4.21 ± 0.59; 3.90 ± 0.53, respectively) on a 5-point Likert scale. There were no significant differences in changes in NT-proBNP or edema index during follow-up between groups. Worsening NYHA class occurred less frequently in the home BIA group (10.0% vs. 31.6%; P = 0.095). Changes in the edema index correlated with changes in NT-proBNP (r = 0.544; P = 0.002), whereas changes in body weight did not (r = 0.237; P = 0.147). No HF hospitalizations or deaths occurred. CONCLUSIONS: Home-based BIA monitoring with preemptive management is feasible, acceptable, and safe for patients with HF.

ESC Heart Failure
Korea University (KR), Soonchunhyang University (KR), Severance Hospital (KR), Korea University Medical Center (KR), Soonchunhyang University Hospital Seoul (KR), Gangnam Severance Hospital (KR), Korea University (JP), Bucheon University (KR)
Clean water and sanitation
Openalex Percentile: Top 19%
Body Composition Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.