Inert gas extinguishing systems: Standard and non-standard suppression testing

Total flooding inert gas extinguishing systems are used to protect facilities that cannot use water-based systems, such as in server rooms and computing facilities. While the standardized approval test for these systems utilizes a wooden crib and three arrays of plastic sheets to represent real-world combustibles, questions remain about the applicability of the Standardized Total Flooding Test results to the real world. Further, defining extinction within the context of inert gas discharge systems is difficult, and often, visual observations are used. To assess the Standardized Test methodology and investigate the extinction dynamics of inert gas systems, burning standard wood cribs, nonstandard wood cribs, polymeric materials, intact desktop computer towers, and an intact server were exposed to total flooding inert gas discharges. To test the limits of extinction, two nonstandard discharge periods, 41 s and 285 s, were utilized in addition to the standard 60 s and 120 s discharge periods. Testing was performed in a full-scale 100 m 3 compartment and a recently developed reduced-scale 33 m 3 enclosure. The average oxygen extinguishing concentration for each test article was measured, and an analysis of the extinction dynamics is presented. • Inert gas suppression testing with nonstandard discharge periods. • Design and analysis of nonstandard wood cribs. • Suppression testing with intact desktop computer towers and a server. • Analysis of extinction dynamics.

Authors

Institutions

Publication Details

Journal
Fire Safety Journal
Published
2026-04-16
DOI
https://doi.org/10.1016/j.firesaf.2026.104835
Primary Topic
Scientific Measurement and Uncertainty Evaluation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Inert gas extinguishing systems: Standard and non-standard suppression testing

Jon Zimak, Albert Simeoni
Fire Safety Journal
Scientific Measurement and Uncertainty Evaluation
article

Inert gas extinguishing systems: Standard and non-standard suppression testing

Jon Zimak, Albert Simeoni
article en

Abstract

Total flooding inert gas extinguishing systems are used to protect facilities that cannot use water-based systems, such as in server rooms and computing facilities. While the standardized approval test for these systems utilizes a wooden crib and three arrays of plastic sheets to represent real-world combustibles, questions remain about the applicability of the Standardized Total Flooding Test results to the real world. Further, defining extinction within the context of inert gas discharge systems is difficult, and often, visual observations are used. To assess the Standardized Test methodology and investigate the extinction dynamics of inert gas systems, burning standard wood cribs, nonstandard wood cribs, polymeric materials, intact desktop computer towers, and an intact server were exposed to total flooding inert gas discharges. To test the limits of extinction, two nonstandard discharge periods, 41 s and 285 s, were utilized in addition to the standard 60 s and 120 s discharge periods. Testing was performed in a full-scale 100 m 3 compartment and a recently developed reduced-scale 33 m 3 enclosure. The average oxygen extinguishing concentration for each test article was measured, and an analysis of the extinction dynamics is presented. • Inert gas suppression testing with nonstandard discharge periods. • Design and analysis of nonstandard wood cribs. • Suppression testing with intact desktop computer towers and a server. • Analysis of extinction dynamics.

Fire Safety JournalVol. 163
Worcester Polytechnic Institute (US)
Affordable and clean energy
Openalex Percentile: Top 11%
Scientific Measurement and Uncertainty Evaluation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Inert gas extinguishing systems: Standard and non-standard suppression testing — Jon Zimak, Albert Simeoni · Fire Safety Journal (2026) | TGRS Research Map | TGRS