Absolute Molecular Weight Distribution of Cellulose in DMSO/EmimOAc (1%) with MALS Detection

This paper presents a method for the measurement of absolute molecular weight of cellulose using a multi-angle light scattering (MALS) detector in 99% dimethyl sulfoxide/1% 1-Ethyl-3-methylimidazolium acetate (DMSO/EmimOAc). The paper also delivers a suitable dn/dc value for cellulose in this solvent. It discusses the pros and cons of using absolute molecular weight measurements versus traditional column calibration in this solvent. The conclusion is that the dn/dc for cellulose in this solvent is 0.049 ± 0.003 mL/g. Absolute molecular weight measurements in this solvent are somewhat beneficial for celluloses with Mw > 250 kg/mol. However, for low-Mw celluloses (e.g., Avicel), it has severe limitations. Herein, it is confirmed that the DMSO/EmimOAc system can be used to replace the traditional DMAc/LiCl system for cellulose molecular weight analysis of some cellulose materials. However, the former is more costly and time-consuming than the latter.

Authors

Institutions

Publication Details

Journal
Polysaccharides
Published
2026-04-16
DOI
https://doi.org/10.3390/polysaccharides7020047
Primary Topic
Advanced Cellulose Research Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Absolute Molecular Weight Distribution of Cellulose in DMSO/EmimOAc (1%) with MALS Detection

Ola Sundman
Polysaccharides
Advanced Cellulose Research Studies
article

Absolute Molecular Weight Distribution of Cellulose in DMSO/EmimOAc (1%) with MALS Detection

Ola Sundman
article en

Abstract

This paper presents a method for the measurement of absolute molecular weight of cellulose using a multi-angle light scattering (MALS) detector in 99% dimethyl sulfoxide/1% 1-Ethyl-3-methylimidazolium acetate (DMSO/EmimOAc). The paper also delivers a suitable dn/dc value for cellulose in this solvent. It discusses the pros and cons of using absolute molecular weight measurements versus traditional column calibration in this solvent. The conclusion is that the dn/dc for cellulose in this solvent is 0.049 ± 0.003 mL/g. Absolute molecular weight measurements in this solvent are somewhat beneficial for celluloses with Mw > 250 kg/mol. However, for low-Mw celluloses (e.g., Avicel), it has severe limitations. Herein, it is confirmed that the DMSO/EmimOAc system can be used to replace the traditional DMAc/LiCl system for cellulose molecular weight analysis of some cellulose materials. However, the former is more costly and time-consuming than the latter.

PolysaccharidesVol. 7(2)
Umeå University (SE)
Openalex Percentile: Top 12%
Advanced Cellulose Research Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.