Design and first experimental results of an edgeless PET prototype for breast imaging: DeepBreast

BACKGROUND: Breast cancer causes the largest number of cancer-related deaths among women worldwide. With the aim of improving Positron Emission Tomography (PET) technology for accurate breast cancer diagnosis and staging, we propose a system design based on monolithic crystals with inherent Depth of Interaction (DOI) capabilities and an innovative edgeless detector ring. This approach eliminates the physical gaps between PET detectors, improving the system detection efficiency while potentially enhancing the image quality since edge effects are reduced. We have developed a dedicated breast PET system prototype (DeepBreast) to show the feasibility of this design. The system is composed of 14 curved LYSO monolithic scintillators of 12.5 mm thickness glued side-by-side with a high-refractive index compound. The useful transaxial and axial Field of View (FOV) of the system are 160 mm and 50 mm, respectively. A Neural Network technique was used for the x- and y- photon impact position estimation. The impact DOI and energy values were determined using the Voronoi calibration methodology. An initial experimental evaluation of the DeepBreast system has been performed inspired by the NEMA protocols for whole-body and small-animals PET scanners. RESULTS: A nearly flat spatial resolution as a function of radial position was obtained, which indicates the DOI capability of the system to mitigate parallax errors. An average spatial resolution of 1.9 ± 0.1 mm, 1.9 ± 0.1 mm and 1.7 ± 0.1 mm FWHM was achieved at the center of the axial FOV for the radial, tangential, and axial directions, respectively. A maximum sensitivity value of 2% was measured at the center of the FOV. The noise equivalent count rate peak reached 15 kcps at 13.4 MBq. Moreover, percent contrast values of 27.9%, 28.8%, 56.8%, 72.5%, 87.2% and 84.2% were achieved for 4.5 mm, 6 mm, 9 mm, 12 mm, 15 mm and 20 mm cylinders of a larger dedicated IQ phantom, respectively. CONCLUSIONS: The initial experimental results demonstrate the feasibility of the DeepBreast as an innovative PET scanner for breast cancer imaging.

Authors

Institutions

Publication Details

Journal
EJNMMI Physics
Published
2026-04-16
DOI
https://doi.org/10.1186/s40658-026-00869-1
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and first experimental results of an edgeless PET prototype for breast imaging: DeepBreast

Julio Barberá, Irene Torres-Espallardo, Santiago Jiménez-Serrano, Francis Loignon-Houle et al.
EJNMMI Physics
Medical Imaging Techniques and Applications
article

Design and first experimental results of an edgeless PET prototype for breast imaging: DeepBreast

Julio Barberá, Irene Torres-Espallardo, Santiago Jiménez-Serrano, Francis Loignon-Houle, Andrea Gonzalez‐Montoro, F. Sánchez, Marta Freire, Sara Echegoyen, J. Álamo, Luis F. Vidal, Carlos de Alfonso, José F. Toledo, Francisco B. García, María J. Rodríguez-Álvarez, Antonio J. González
article en

Abstract

BACKGROUND: Breast cancer causes the largest number of cancer-related deaths among women worldwide. With the aim of improving Positron Emission Tomography (PET) technology for accurate breast cancer diagnosis and staging, we propose a system design based on monolithic crystals with inherent Depth of Interaction (DOI) capabilities and an innovative edgeless detector ring. This approach eliminates the physical gaps between PET detectors, improving the system detection efficiency while potentially enhancing the image quality since edge effects are reduced. We have developed a dedicated breast PET system prototype (DeepBreast) to show the feasibility of this design. The system is composed of 14 curved LYSO monolithic scintillators of 12.5 mm thickness glued side-by-side with a high-refractive index compound. The useful transaxial and axial Field of View (FOV) of the system are 160 mm and 50 mm, respectively. A Neural Network technique was used for the x- and y- photon impact position estimation. The impact DOI and energy values were determined using the Voronoi calibration methodology. An initial experimental evaluation of the DeepBreast system has been performed inspired by the NEMA protocols for whole-body and small-animals PET scanners. RESULTS: A nearly flat spatial resolution as a function of radial position was obtained, which indicates the DOI capability of the system to mitigate parallax errors. An average spatial resolution of 1.9 ± 0.1 mm, 1.9 ± 0.1 mm and 1.7 ± 0.1 mm FWHM was achieved at the center of the axial FOV for the radial, tangential, and axial directions, respectively. A maximum sensitivity value of 2% was measured at the center of the FOV. The noise equivalent count rate peak reached 15 kcps at 13.4 MBq. Moreover, percent contrast values of 27.9%, 28.8%, 56.8%, 72.5%, 87.2% and 84.2% were achieved for 4.5 mm, 6 mm, 9 mm, 12 mm, 15 mm and 20 mm cylinders of a larger dedicated IQ phantom, respectively. CONCLUSIONS: The initial experimental results demonstrate the feasibility of the DeepBreast as an innovative PET scanner for breast cancer imaging.

EJNMMI Physics
Hospital Universitari i Politècnic La Fe (ES), Instituto de Instrumentación para Imagen Molecular (ES), Oncovision (Spain) (ES)
Consejo Superior de Investigaciones Científicas
Good health and well-being
Openalex Percentile: Top 13%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.