Operational checks for real-time urinary biomarker measurements for assessment of the quality of deceased donor kidneys

Lateral flow devices (LFDs) were integrated into the clinical organ procurement workflow of two organ procurement organizations (OPOs) to obtain measurements of urinary biomarkers uromodulin (UMOD), osteopontin (OPN), and chitinase-3-like protein 1 (YKL-40) in deceased donors. We report on the feasibility of expanding the procurement workflow with this point-of-care testing, as well as methods of monitoring study performance and sample integrity through quality checks (QCs). Data QCs were implemented at OPO sample collection, transport/storage, processing, sample shipment back to the data coordinating center, and data transcription. From April 2022 to April 2025, 62 laboratory staff at two OPOs measured repair biomarkers of 958 samples from 879 unique donors. 4% of samples (n = 35) were excluded due to sample QCs, such as being left unfrozen beyond acceptable protocol ranges. These exclusions resulted in 923 samples from 851 unique donors [720 donors after brain death (DBD), 131 donors after circulatory death (DCD)]. Median processing time of LFD biomarker measurements across OPOs was 46 min (IQR: 40–55) and 5.1% cases required LFD remeasurement due to invalid readings. Developed QCs were used to identify samples suitable for research purposes and have been summarized into a checklist for use in multidisciplinary sciences.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-04-16
DOI
https://doi.org/10.1038/s41598-026-48155-5
Primary Topic
Organ Donation and Transplantation
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Operational checks for real-time urinary biomarker measurements for assessment of the quality of deceased donor kidneys

Mitali Barik, Wassim Obeid, Wrenn Woodard, Elyssa Gansner et al.
Scientific Reports
Organ Donation and Transplantation
article

Operational checks for real-time urinary biomarker measurements for assessment of the quality of deceased donor kidneys

Mitali Barik, Wassim Obeid, Wrenn Woodard, Elyssa Gansner, Gary Marklin, Heather Thiessen Philbrook, Serena DSouza, Mona Doshi, David Hu, Chirag R. Parikh, Walter Herczyk, Sophia Xu, Nick Olden, Sumit Mohan
article en

Abstract

Lateral flow devices (LFDs) were integrated into the clinical organ procurement workflow of two organ procurement organizations (OPOs) to obtain measurements of urinary biomarkers uromodulin (UMOD), osteopontin (OPN), and chitinase-3-like protein 1 (YKL-40) in deceased donors. We report on the feasibility of expanding the procurement workflow with this point-of-care testing, as well as methods of monitoring study performance and sample integrity through quality checks (QCs). Data QCs were implemented at OPO sample collection, transport/storage, processing, sample shipment back to the data coordinating center, and data transcription. From April 2022 to April 2025, 62 laboratory staff at two OPOs measured repair biomarkers of 958 samples from 879 unique donors. 4% of samples (n = 35) were excluded due to sample QCs, such as being left unfrozen beyond acceptable protocol ranges. These exclusions resulted in 923 samples from 851 unique donors [720 donors after brain death (DBD), 131 donors after circulatory death (DCD)]. Median processing time of LFD biomarker measurements across OPOs was 46 min (IQR: 40–55) and 5.1% cases required LFD remeasurement due to invalid readings. Developed QCs were used to identify samples suitable for research purposes and have been summarized into a checklist for use in multidisciplinary sciences.

Scientific Reports
Johns Hopkins University (US), University of Michigan (US), Johns Hopkins Medicine (US), Gift of Life Michigan (US), Columbia University (US)
Vanderbilt University, National Institutes of Health
Quality Education
Openalex Percentile: Top 16%
Organ Donation and Transplantation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.