Development and validation of a fully automated transformer-based 3D framework for pancreatic fat quantification in pancreatic steatosis

Purpose: To develop and validate a fully automated TransUNet-based framework for 3D pancreatic segmentation and volumetric fat quantification on PDFF MRI. Specifically, to evaluate the model's performance against state-of-the-art CNN architectures and assess its clinical reproducibility compared to manual reference methods. Methods: This retrospective study involved 140 adults with metabolic dysfunction-associated steatotic liver disease who underwent 3.0 T multi-echo mDIXON MRI. A TransUNet-based model was developed using a 5-fold cross-validation approach, integrating convolutional and transformer layers to capture global and local features. Various architectures (UNet, nnUNet) and multiple input combinations of water, fat, and R2* maps were systematically compared. Segmentation performance was primarily assessed using the Dice Similarity Coefficient (DSC), with the Jaccard index, precision, recall, and 95th-percentile Hausdorff distance additionally used for network comparison. Agreement of pancreatic fat quantification across measurement methods was assessed using Bland-Altman analysis and intraclass correlation coefficients (ICC). Results: TransUNet achieved the highest segmentation accuracy (DSC: 85.46%, IQR: 80.76-86.24%), outperforming nnUNet (84.24%) and UNet (71.89%). Optimal performance was reached using water-only and fat-only input series. The AI-based volumetric method demonstrated strong agreement with manual whole-organ PDFF (r = 0.866, p < 0.001) with a minimal mean bias (1.20). Conversely, 2D ROI methods significantly underestimated pancreatic fat (6.08 ± 2.74%) compared to both manual (21.95 ± 6.14%) and AI-based (20.72 ± 6.13%) volumetric assessments (p < 0.001). Conclusion: TransUNet provides accurate, reproducible 3D pancreatic segmentation and fat quantification. By capturing the entire organ volume, this automated framework overcomes the sampling bias inherent in traditional 2D ROI methods, offering a fast and reliable biomarker for pancreatic steatosis.

Authors

Institutions

Publication Details

Journal
European Journal of Radiology Open
Published
2026-04-17
DOI
https://doi.org/10.1016/j.ejro.2026.100749
Primary Topic
Pancreatitis Pathology and Treatment
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and validation of a fully automated transformer-based 3D framework for pancreatic fat quantification in pancreatic steatosis

Chileka Chiyanika, Raymond Shing Yan Tang, Gary Ge Ren, Winnie Chu et al.
European Journal of Radiology Open
Pancreatitis Pathology and Treatment
article

Development and validation of a fully automated transformer-based 3D framework for pancreatic fat quantification in pancreatic steatosis

Chileka Chiyanika, Raymond Shing Yan Tang, Gary Ge Ren, Winnie Chu, You Pang
article en

Abstract

Purpose: To develop and validate a fully automated TransUNet-based framework for 3D pancreatic segmentation and volumetric fat quantification on PDFF MRI. Specifically, to evaluate the model's performance against state-of-the-art CNN architectures and assess its clinical reproducibility compared to manual reference methods. Methods: This retrospective study involved 140 adults with metabolic dysfunction-associated steatotic liver disease who underwent 3.0 T multi-echo mDIXON MRI. A TransUNet-based model was developed using a 5-fold cross-validation approach, integrating convolutional and transformer layers to capture global and local features. Various architectures (UNet, nnUNet) and multiple input combinations of water, fat, and R2* maps were systematically compared. Segmentation performance was primarily assessed using the Dice Similarity Coefficient (DSC), with the Jaccard index, precision, recall, and 95th-percentile Hausdorff distance additionally used for network comparison. Agreement of pancreatic fat quantification across measurement methods was assessed using Bland-Altman analysis and intraclass correlation coefficients (ICC). Results: TransUNet achieved the highest segmentation accuracy (DSC: 85.46%, IQR: 80.76-86.24%), outperforming nnUNet (84.24%) and UNet (71.89%). Optimal performance was reached using water-only and fat-only input series. The AI-based volumetric method demonstrated strong agreement with manual whole-organ PDFF (r = 0.866, p < 0.001) with a minimal mean bias (1.20). Conversely, 2D ROI methods significantly underestimated pancreatic fat (6.08 ± 2.74%) compared to both manual (21.95 ± 6.14%) and AI-based (20.72 ± 6.13%) volumetric assessments (p < 0.001). Conclusion: TransUNet provides accurate, reproducible 3D pancreatic segmentation and fat quantification. By capturing the entire organ volume, this automated framework overcomes the sampling bias inherent in traditional 2D ROI methods, offering a fast and reliable biomarker for pancreatic steatosis.

European Journal of Radiology OpenVol. 16
Hong Kong Polytechnic University (HK), Chinese University of Hong Kong (HK), Prince of Wales Hospital (CN)
Hong Kong Polytechnic University
Zero hunger
Openalex Percentile: Top 25%
Pancreatitis Pathology and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.