Ag-Doped ZnO Quantum Dots for Fluorescence-Based Detection of Trace Cr(VI) from River Water and Fish samples

The co-precipitation process was used to create silver-doped zinc oxide. Fluorescence spectrophotometry, XRD, FT-IR, BET, TGA, and UV-Vis were used to characterize it. When stimulated at 360 nm, the Ag/ZnO QDs displayed intense fluorescence emission at 508 nm and were highly selective for Cr(VI). A calibration curve was plotted for different concentration levels of Cr(VI) ranging from 0 to 12 mg/L, with an R² value of 0.998 and the LOD and LOQ at 3.2 µg/L and 11 µg/L, respectively. Three concentration levels, 0.8, 5.6, and 10.4 mg/L, were used to examine the precision of the devised approach; relative standard deviation values did not surpass 5.4%, showing good reproducibility. By adding known quantities of Cr(VI) to the water and fish samples, the method’s recovery was assessed; the results ranged from 77.5% to 112.5%. Ultimately, the suggested approach demonstrated outstanding sensitivity, selectivity, and repeatability for the detection of Cr(VI) in fish and water samples.

Authors

Institutions

Publication Details

Journal
Journal of Fluorescence
Published
2026-04-16
DOI
https://doi.org/10.1007/s10895-026-04750-3
Primary Topic
Carbon and Quantum Dots Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ag-Doped ZnO Quantum Dots for Fluorescence-Based Detection of Trace Cr(VI) from River Water and Fish samples

Abera Gure, Shimeles Addisu Kitte, Tamene Tadesse Beyene, Genet Aregay Shifera
Journal of Fluorescence
Carbon and Quantum Dots Applications
article

Ag-Doped ZnO Quantum Dots for Fluorescence-Based Detection of Trace Cr(VI) from River Water and Fish samples

Abera Gure, Shimeles Addisu Kitte, Tamene Tadesse Beyene, Genet Aregay Shifera
article en

Abstract

The co-precipitation process was used to create silver-doped zinc oxide. Fluorescence spectrophotometry, XRD, FT-IR, BET, TGA, and UV-Vis were used to characterize it. When stimulated at 360 nm, the Ag/ZnO QDs displayed intense fluorescence emission at 508 nm and were highly selective for Cr(VI). A calibration curve was plotted for different concentration levels of Cr(VI) ranging from 0 to 12 mg/L, with an R² value of 0.998 and the LOD and LOQ at 3.2 µg/L and 11 µg/L, respectively. Three concentration levels, 0.8, 5.6, and 10.4 mg/L, were used to examine the precision of the devised approach; relative standard deviation values did not surpass 5.4%, showing good reproducibility. By adding known quantities of Cr(VI) to the water and fish samples, the method’s recovery was assessed; the results ranged from 77.5% to 112.5%. Ultimately, the suggested approach demonstrated outstanding sensitivity, selectivity, and repeatability for the detection of Cr(VI) in fish and water samples.

Journal of Fluorescence
Jimma University (ET)
Jimma University
Clean water and sanitation
Openalex Percentile: Top 19%
Carbon and Quantum Dots Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.