Role of automated insulin delivery (AID) systems in glucose control in patients with diabetes mellitus undergoing dialysis in Calabria: AID-DIAL-CAL

AIMS: To describe the main glycemic outcomes and the Quality of Life (QOL) observed in a cohort of people with type 1 (T1D) or type 2 (T2D) insulin-treated diabetes under dialysis who started an Automated Insulin Delivery (AID) system. METHODS: This is a longitudinal retrospective pilot real-world analysis of 14 individuals with T1D and T2D undergoing dialysis who began using an AID system to optimize glycemic control. All subjects used the MiniMed™ 780G system. Glucose metrics were collected at baseline, 3, 6, and 12 months after initiating the SmartGuard™ feature. The WHOQoL-Bref questionnaire was administered at the last follow-up to evaluate the QOL. RESULTS: Out of the 14 people, 8 reached 1-year follow-up. Time in Range (TIR) increased from 63% at baseline to 69% at 12 months, Time Below Range < 70 mg/dL (TBR70) decreased from 0.3% to 0%, and Time Above Range > 250 mg/dL (TAR250) decreased from 6.7% to 3.9%. Seven out of eight subjects who reached a 12-month follow-up achieved all three glycemic targets for this fragile population (TIR > 50%, TBR70 < 1% and TAR250 < 10%). At the last follow-up, 58.3% of the users were satisfied or very satisfied with their health status, versus only 25% with the previous treatment, and 81.7% had a good or very good QOL, whereas only 8.3% had a good QOL, and no one had a very good QOL with the previous treatment. CONCLUSION: This pilot real-world study showed how the use of an AID system is safe and can help to improve the glycemic outcomes and the QOL of people with diabetes in dialysis.

Authors

Institutions

Publication Details

Journal
Acta Diabetologica
Published
2026-04-15
DOI
https://doi.org/10.1007/s00592-026-02690-9
Primary Topic
Diabetes Management and Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Role of automated insulin delivery (AID) systems in glucose control in patients with diabetes mellitus undergoing dialysis in Calabria: AID-DIAL-CAL

Raffaele Mancini, Elena Succurro, Ilaria Gattuso, Francesco Andreozzi et al.
Acta Diabetologica
Diabetes Management and Research
article

Role of automated insulin delivery (AID) systems in glucose control in patients with diabetes mellitus undergoing dialysis in Calabria: AID-DIAL-CAL

Raffaele Mancini, Elena Succurro, Ilaria Gattuso, Francesco Andreozzi, Michele Andreucci, Ramona Nicotera, Maria Capria, Giovanni Mazzitello, Fiorella Iorio, Roberta Arena, Francesco Brisinda, Giuseppe Cersosimo, Giuseppe Fabiano, Paola Sarnelli, Valeria Mazza, Gianluigi Zaza
article en

Abstract

AIMS: To describe the main glycemic outcomes and the Quality of Life (QOL) observed in a cohort of people with type 1 (T1D) or type 2 (T2D) insulin-treated diabetes under dialysis who started an Automated Insulin Delivery (AID) system. METHODS: This is a longitudinal retrospective pilot real-world analysis of 14 individuals with T1D and T2D undergoing dialysis who began using an AID system to optimize glycemic control. All subjects used the MiniMed™ 780G system. Glucose metrics were collected at baseline, 3, 6, and 12 months after initiating the SmartGuard™ feature. The WHOQoL-Bref questionnaire was administered at the last follow-up to evaluate the QOL. RESULTS: Out of the 14 people, 8 reached 1-year follow-up. Time in Range (TIR) increased from 63% at baseline to 69% at 12 months, Time Below Range < 70 mg/dL (TBR70) decreased from 0.3% to 0%, and Time Above Range > 250 mg/dL (TAR250) decreased from 6.7% to 3.9%. Seven out of eight subjects who reached a 12-month follow-up achieved all three glycemic targets for this fragile population (TIR > 50%, TBR70 < 1% and TAR250 < 10%). At the last follow-up, 58.3% of the users were satisfied or very satisfied with their health status, versus only 25% with the previous treatment, and 81.7% had a good or very good QOL, whereas only 8.3% had a good QOL, and no one had a very good QOL with the previous treatment. CONCLUSION: This pilot real-world study showed how the use of an AID system is safe and can help to improve the glycemic outcomes and the QOL of people with diabetes in dialysis.

Acta Diabetologica
Magna Graecia University (IT), Azienda Ospedaliera di Cosenza (IT), Azienda Sanitaria Locale Viterbo (IT), Ospedale Annunziata di Cosenza (IT), Accademia di Belle Arti di Catanzaro (IT), University of Calabria (IT)
Openalex Percentile: Top 23%
Diabetes Management and Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.