Reliability of ultra-thin metal films integrated onto embossed and bonded liquid-crystal-polymer (LCP) sheets for neural-interface applications

Liquid crystal polymer (LCP) is increasingly used in flexible implantable bioelectronic devices due to its low moisture uptake, chemical stability, and ability to form robust thermoplastic bonds. However, integrating fine-pitch thin-film metallization into bonded embossed LCP structures presents challenges related to pattern fidelity, bond integrity, alignment accuracy, and long-term electrical reliability, particularly when the metal thickness is small relative to the surface roughness. In this work, we present and characterize a fabrication process for integrating a 500-nm-thick sputtered Cr/Au thin-film metallization onto a 25-μm-thick embossed high-temperature LCP (HT-LCP) substrate, patterned into long (20 cm) and narrow (8 μm) traces using lift-off. Bond integrity between the metallized HT-LCP and a low-temperature LCP (LT-LCP) layer was evaluated using peel testing, while structural and electrical integrity were assessed using NanoCT imaging and resistance measurements. Long-term reliability was evaluated using reactive accelerated aging (RAA) at 87 °C in physiological saline with 10 mM hydrogen peroxide. The results show that the thin metal layer does not degrade bond strength and that embedded traces maintain structural and electrical integrity through bonding and aging. After 12 days of RAA testing, no measurable changes in electrical performance were observed. Electrochemical impedance spectroscopy demonstrated that electrodes coated with a 100-nm sputtered Pt layer exhibited approximately 2 × lower impedance than flat Pt electrodes, attributed to increased surface roughness. Additionally, the bonded LCP structure was thinned from 50 μm to 10 μm using CF4/O2 reactive ion etching with >90% uniformity. These results demonstrate that thin-film metallization integrated into bonded embossed LCP systems can achieve high interconnect density without compromising mechanical or electrical reliability. This work provides practical guidelines for the design of thin, flexible, and durable LCP-based implantable bioelectronic devices.

Authors

Institutions

Publication Details

Journal
Frontiers in Neuroscience
Published
2026-04-15
DOI
https://doi.org/10.3389/fnins.2026.1810147
Primary Topic
Neuroscience and Neural Engineering
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reliability of ultra-thin metal films integrated onto embossed and bonded liquid-crystal-polymer (LCP) sheets for neural-interface applications

Jack W. Judy, Ladan Jiracek, Ryan S. Wilkerson
Frontiers in Neuroscience
Neuroscience and Neural Engineering
article

Reliability of ultra-thin metal films integrated onto embossed and bonded liquid-crystal-polymer (LCP) sheets for neural-interface applications

Jack W. Judy, Ladan Jiracek, Ryan S. Wilkerson
article en

Abstract

Liquid crystal polymer (LCP) is increasingly used in flexible implantable bioelectronic devices due to its low moisture uptake, chemical stability, and ability to form robust thermoplastic bonds. However, integrating fine-pitch thin-film metallization into bonded embossed LCP structures presents challenges related to pattern fidelity, bond integrity, alignment accuracy, and long-term electrical reliability, particularly when the metal thickness is small relative to the surface roughness. In this work, we present and characterize a fabrication process for integrating a 500-nm-thick sputtered Cr/Au thin-film metallization onto a 25-μm-thick embossed high-temperature LCP (HT-LCP) substrate, patterned into long (20 cm) and narrow (8 μm) traces using lift-off. Bond integrity between the metallized HT-LCP and a low-temperature LCP (LT-LCP) layer was evaluated using peel testing, while structural and electrical integrity were assessed using NanoCT imaging and resistance measurements. Long-term reliability was evaluated using reactive accelerated aging (RAA) at 87 °C in physiological saline with 10 mM hydrogen peroxide. The results show that the thin metal layer does not degrade bond strength and that embedded traces maintain structural and electrical integrity through bonding and aging. After 12 days of RAA testing, no measurable changes in electrical performance were observed. Electrochemical impedance spectroscopy demonstrated that electrodes coated with a 100-nm sputtered Pt layer exhibited approximately 2 × lower impedance than flat Pt electrodes, attributed to increased surface roughness. Additionally, the bonded LCP structure was thinned from 50 μm to 10 μm using CF4/O2 reactive ion etching with >90% uniformity. These results demonstrate that thin-film metallization integrated into bonded embossed LCP systems can achieve high interconnect density without compromising mechanical or electrical reliability. This work provides practical guidelines for the design of thin, flexible, and durable LCP-based implantable bioelectronic devices.

Frontiers in NeuroscienceVol. 20
University of Florida (US)
National Institute for Health and Care Research
Openalex Percentile: Top 24%
Neuroscience and Neural Engineering
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.