Optimizing Single-Lead Electrocardiogram Orientation Improves Detection of Left Ventricular Dysfunction

BACKGROUND: Single-lead electrocardiograms (ECGs) contain subtle markers of left ventricular (LV) dysfunction. We hypothesized that a synthesized frontal-plane vector would improve single-lead detection of reduced LV ejection fraction (LVEF) compared with standard limb leads. METHODS AND RESULTS: This diagnostic study used paired 12-lead ECGs (10 s, 500 Hz) and echocardiograms obtained within 30 days from three Japanese hospital cohorts (one development and two external validation cohorts). For each beat, a derived lead, X, was synthesized from limb leads I and II as X(θ) = cosθ · I + sinθ · II, with θ scanned from 0° to 360°. A deep neural network generated beat-level predictions aggregated per recording to detect LVEF <50%. AUROC was the primary metric; accuracy, F1 score, sensitivity, and specificity were secondary metrics. Two performance peaks emerged near 30° and 210° (AUROC ≈0.857). Across repeated modeling from 180° to 270°, the 210° lead consistently ranked among the best single-lead models, matching or slightly exceeding aVR, although the 12-lead model remained superior. In external cohorts, the 210° lead achieved mean (±SD) AUROC 0.863±0.031, comparable to 12-lead and aVR (0.872±0.024 and 0.852±0.032; P>0.05). CONCLUSIONS: An aVR-adjacent frontal vector near 210° enables single-lead detection of LV dysfunction that approaches 12-lead performance and exceeds other individual leads. Requiring only standard limb electrodes, this strategy could facilitate screening; further validation and mechanistic studies are warranted.

Authors

Institutions

Publication Details

Journal
Circulation Journal
Published
2026-04-15
DOI
https://doi.org/10.1253/circj.cj-25-0955
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimizing Single-Lead Electrocardiogram Orientation Improves Detection of Left Ventricular Dysfunction

Norihiko Takeda, Yukiyo Ogata, Takayuki Okatani, Masashi Kamioka et al.
Circulation Journal
ECG Monitoring and Analysis
article

Optimizing Single-Lead Electrocardiogram Orientation Improves Detection of Left Ventricular Dysfunction

Norihiko Takeda, Yukiyo Ogata, Takayuki Okatani, Masashi Kamioka, Hisaki Makimoto, Tomoyuki Kabutoya, Shinnosuke Sawano, Tetsuya Matoba, Kenji Harada, Ayako Yokota, Masafumi Sato, K. Anno, T Komori, Y Imai, Tomonori Watanabe, Hiroaki Watanabe, Takahide Kohro, Ryozo Nagai, Kazuomi Kario, Satoshi Kodera
article en

Abstract

BACKGROUND: Single-lead electrocardiograms (ECGs) contain subtle markers of left ventricular (LV) dysfunction. We hypothesized that a synthesized frontal-plane vector would improve single-lead detection of reduced LV ejection fraction (LVEF) compared with standard limb leads. METHODS AND RESULTS: This diagnostic study used paired 12-lead ECGs (10 s, 500 Hz) and echocardiograms obtained within 30 days from three Japanese hospital cohorts (one development and two external validation cohorts). For each beat, a derived lead, X, was synthesized from limb leads I and II as X(θ) = cosθ · I + sinθ · II, with θ scanned from 0° to 360°. A deep neural network generated beat-level predictions aggregated per recording to detect LVEF <50%. AUROC was the primary metric; accuracy, F1 score, sensitivity, and specificity were secondary metrics. Two performance peaks emerged near 30° and 210° (AUROC ≈0.857). Across repeated modeling from 180° to 270°, the 210° lead consistently ranked among the best single-lead models, matching or slightly exceeding aVR, although the 12-lead model remained superior. In external cohorts, the 210° lead achieved mean (±SD) AUROC 0.863±0.031, comparable to 12-lead and aVR (0.872±0.024 and 0.852±0.032; P>0.05). CONCLUSIONS: An aVR-adjacent frontal vector near 210° enables single-lead detection of LV dysfunction that approaches 12-lead performance and exceeds other individual leads. Requiring only standard limb electrodes, this strategy could facilitate screening; further validation and mechanistic studies are warranted.

Circulation Journal
Kyushu University (JP), Jichi Medical University (JP), Tohoku University (JP), University of Tokyo Hospital (JP), Jichi Medical University Hospital (JP), The University of Tokyo (JP)
Openalex Percentile: Top 23%
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.