Adaptive design and multi–material additive manufacturing of a rigid–flexible lower–limb prosthetic socket featuring shape–performance synergy

The lower–limb prosthetic socket serves as the critical interface connecting the residual limb to the prosthesis for load transfer and mobility restoration. Relying on static geometry and rigid materials, conventional sockets hinder tissue–specific load distribution and cannot accommodate gait–induced mismatches, compromising wearing comfort and functionality. To address these limitations, a quantitative design strategy for rigid–flexible sockets was proposed, leveraging finite element analysis (FEA) to iteratively optimise topology for precise load regulation and soft–tissue accommodation. A multi–material additive manufacturing strategy incorporating continuous fiber reinforcement was tailored to address heterogeneous interface demands and overcome inherent interlayer weakness. Results indicate that the optimised rigid structure effectively redistributed loads toward load–tolerant muscle groups, while the flexible structure mitigated gait–induced pressure peaks by up to 37.1%. The fabrication strategy improved the bonding strength at the heterogeneous interface by 1.5 times and the vertical tensile strength by 8.1 times compared to unreinforced counterparts. Clinical results validated the simulations, showing a 39.7% pressure reduction and superior subjective comfort. Collectively, this study establishes a comprehensive framework for the design, fabrication, and evaluation of rigid–flexible sockets, providing a quantifiable design method for patient–centered rehabilitation devices.

Authors

Institutions

Publication Details

Journal
Virtual and Physical Prototyping
Published
2026-04-15
DOI
https://doi.org/10.1080/17452759.2026.2646822
Primary Topic
Prosthetics and Rehabilitation Robotics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Adaptive design and multi–material additive manufacturing of a rigid–flexible lower–limb prosthetic socket featuring shape–performance synergy

Ziyan Qiu, W T Zhang, D C Li, Zi Wang et al.
Virtual and Physical Prototyping
Prosthetics and Rehabilitation Robotics
article

Adaptive design and multi–material additive manufacturing of a rigid–flexible lower–limb prosthetic socket featuring shape–performance synergy

Ziyan Qiu, W T Zhang, D C Li, Zi Wang, Man Li, Fuhao Huang, Siqi Yao, Pingping Wei, Yingjie Liu, Chaozong Liu, Ling Wang, Lei Tang, Changning Sun
article en

Abstract

The lower–limb prosthetic socket serves as the critical interface connecting the residual limb to the prosthesis for load transfer and mobility restoration. Relying on static geometry and rigid materials, conventional sockets hinder tissue–specific load distribution and cannot accommodate gait–induced mismatches, compromising wearing comfort and functionality. To address these limitations, a quantitative design strategy for rigid–flexible sockets was proposed, leveraging finite element analysis (FEA) to iteratively optimise topology for precise load regulation and soft–tissue accommodation. A multi–material additive manufacturing strategy incorporating continuous fiber reinforcement was tailored to address heterogeneous interface demands and overcome inherent interlayer weakness. Results indicate that the optimised rigid structure effectively redistributed loads toward load–tolerant muscle groups, while the flexible structure mitigated gait–induced pressure peaks by up to 37.1%. The fabrication strategy improved the bonding strength at the heterogeneous interface by 1.5 times and the vertical tensile strength by 8.1 times compared to unreinforced counterparts. Clinical results validated the simulations, showing a 39.7% pressure reduction and superior subjective comfort. Collectively, this study establishes a comprehensive framework for the design, fabrication, and evaluation of rigid–flexible sockets, providing a quantifiable design method for patient–centered rehabilitation devices.

Virtual and Physical PrototypingVol. 21(1)
Royal National Orthopaedic Hospital (GB), Xi'an Honghui Hospital (CN), National Research Center for Rehabilitation Technical Aids (CN), Xijing Hospital (CN), University College London (GB), Xi'an Jiaotong University (CN), Air Force Medical University (CN)
National Key Research and Development Program of China
Openalex Percentile: Top 25%
Prosthetics and Rehabilitation Robotics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.