Comparison Between Weight-Based Variable-Voltage and Fixed Volume-Voltage Protocols in Cancer Surveillance Computed Tomography

OBJECTIVE: This study assessed whether the weight-based, variable tube voltage (Bayer MEDRAD Centargo SMART) protocol compared with a fixed contrast, fixed tube voltage (referred to as the 'OLD') protocol for cancer patients undergoing CT chest, abdomen, and pelvis (CAP) scans could reduce contrast dose, without a reduction in contrast enhancement. METHODS: A total of 149 oncology patients, each underwent 2 surveillance CT CAP scans using both the OLD and SMART protocols, typically with a 3-month interval between scans. Contrast volume was recorded for each protocol as well as the CT attenuation measurement Hounsfield unit (HU) at the ascending aorta, pulmonary trunk, right atrial appendage, middle hepatic vein, main portal vein, and renal cortex, as well as dose-length product (DLP, mGy/cm) and CT Dose Index volume (CTDIvol, mGy). RESULTS: The SMART protocol used less contrast per patient with a median volume of 80 versus 100 mL representing a 20% absolute reduction. Quantitative contrast enhancement measurements demonstrated non-inferior HU values in the SMART protocol at all sites. This was achieved with a 19% DLP and 9% CTDIvol decrease in radiation exposure. CONCLUSIONS: The weight-based contrast, variable tube voltage protocol effectively reduces contrast volume without increasing radiation dose and does not reduce contrast enhancement.

Authors

Institutions

Publication Details

Journal
Journal of Computer Assisted Tomography
Published
2026-04-15
DOI
https://doi.org/10.1097/rct.0000000000001865
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison Between Weight-Based Variable-Voltage and Fixed Volume-Voltage Protocols in Cancer Surveillance Computed Tomography

Ashik Amlani, James H. Seow, C J Welman, Kirsten Richards et al.
Journal of Computer Assisted Tomography
Radiation Dose and Imaging
article

Comparison Between Weight-Based Variable-Voltage and Fixed Volume-Voltage Protocols in Cancer Surveillance Computed Tomography

Ashik Amlani, James H. Seow, C J Welman, Kirsten Richards, Eric Williams, Arathy Harikumar, Joseph J. Ipsen, Angela Kilcoyne, Alvin Tanaya
article en

Abstract

OBJECTIVE: This study assessed whether the weight-based, variable tube voltage (Bayer MEDRAD Centargo SMART) protocol compared with a fixed contrast, fixed tube voltage (referred to as the 'OLD') protocol for cancer patients undergoing CT chest, abdomen, and pelvis (CAP) scans could reduce contrast dose, without a reduction in contrast enhancement. METHODS: A total of 149 oncology patients, each underwent 2 surveillance CT CAP scans using both the OLD and SMART protocols, typically with a 3-month interval between scans. Contrast volume was recorded for each protocol as well as the CT attenuation measurement Hounsfield unit (HU) at the ascending aorta, pulmonary trunk, right atrial appendage, middle hepatic vein, main portal vein, and renal cortex, as well as dose-length product (DLP, mGy/cm) and CT Dose Index volume (CTDIvol, mGy). RESULTS: The SMART protocol used less contrast per patient with a median volume of 80 versus 100 mL representing a 20% absolute reduction. Quantitative contrast enhancement measurements demonstrated non-inferior HU values in the SMART protocol at all sites. This was achieved with a 19% DLP and 9% CTDIvol decrease in radiation exposure. CONCLUSIONS: The weight-based contrast, variable tube voltage protocol effectively reduces contrast volume without increasing radiation dose and does not reduce contrast enhancement.

Journal of Computer Assisted Tomography
Royal Perth Hospital (AU), Fiona Stanley Hospital (AU), WA Country Health Service (AU), North Metropolitan Health Service (AU)
Good health and well-being
Openalex Percentile: Top 14%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.