Effect of residual stress distribution on the performance of Micro-electromechanical systems for radio-frequency applications

The performance and reliability of radio-frequency microelectromechanical systems are critically dependent on the stiffness and stress state of their membranes. Although previous studies have demonstrated the potential of nanoindentation to extract elastic properties from simplified bilayer films, the combined effects of multilayer architectures, residual stress gradients, and device geometry in realistic RF-MEMS remain poorly understood. Here, we present the first systematic experimental framework that directly moves beyond average-stress-value measurement and couples depth-resolved Focused Ion Beam–Digital Image Correlation residual-stress profiling with high-resolution nanoindentation to analyze functional TiW/Au/TiW tri-layer MEMS cantilevers and membranes. Unlike prior bilayer model systems, this trilayer configuration is representative of industrial RF switch designs, enabling us to capture both tensile and compressive stress components across the thickness before and after annealing. Our results reveal geometry-independent stress redistribution mechanisms across the multi-layered system's thickness and demonstrate how controlled thermal treatments can tune stiffness, establishing device-level correlations among residual stress, elastic properties, and MEMS functionality, with direct implications for lowering actuation voltage and enhancing switching efficiency. • Depth-resolved residual stress profiling in TiW/Au/TiW MEMS structures • Coupling of FIB–DIC and nanoindentation for device-level stress analysis • Geometry-independent mechanisms of stress redistribution demonstrated • Annealing tunes stiffness and flatness with direct impact on RF performance • Framework enables predictive design of reliable, low-voltage RF-MEMS switches

Authors

Institutions

Publication Details

Journal
Sensors and Actuators A Physical
Published
2026-04-15
DOI
https://doi.org/10.1016/j.sna.2026.117862
Primary Topic
Advanced MEMS and NEMS Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of residual stress distribution on the performance of Micro-electromechanical systems for radio-frequency applications

R. Guillemet, Paolo Martins, Saqib Rashid, Edoardo Rossi et al.
Sensors and Actuators A Physical
Advanced MEMS and NEMS Technologies
article

Effect of residual stress distribution on the performance of Micro-electromechanical systems for radio-frequency applications

R. Guillemet, Paolo Martins, Saqib Rashid, Edoardo Rossi, Marco Sebastiani, Edoardo Bemporad
article en

Abstract

The performance and reliability of radio-frequency microelectromechanical systems are critically dependent on the stiffness and stress state of their membranes. Although previous studies have demonstrated the potential of nanoindentation to extract elastic properties from simplified bilayer films, the combined effects of multilayer architectures, residual stress gradients, and device geometry in realistic RF-MEMS remain poorly understood. Here, we present the first systematic experimental framework that directly moves beyond average-stress-value measurement and couples depth-resolved Focused Ion Beam–Digital Image Correlation residual-stress profiling with high-resolution nanoindentation to analyze functional TiW/Au/TiW tri-layer MEMS cantilevers and membranes. Unlike prior bilayer model systems, this trilayer configuration is representative of industrial RF switch designs, enabling us to capture both tensile and compressive stress components across the thickness before and after annealing. Our results reveal geometry-independent stress redistribution mechanisms across the multi-layered system's thickness and demonstrate how controlled thermal treatments can tune stiffness, establishing device-level correlations among residual stress, elastic properties, and MEMS functionality, with direct implications for lowering actuation voltage and enhancing switching efficiency. • Depth-resolved residual stress profiling in TiW/Au/TiW MEMS structures • Coupling of FIB–DIC and nanoindentation for device-level stress analysis • Geometry-independent mechanisms of stress redistribution demonstrated • Annealing tunes stiffness and flatness with direct impact on RF performance • Framework enables predictive design of reliable, low-voltage RF-MEMS switches

Sensors and Actuators A PhysicalVol. 406
Roma Tre University (IT), Thales (Australia) (AU), National Interuniversity Consortium of Materials Science and Technology (IT), Institute of Polymers, Composites and Biomaterials (IT)
HORIZON EUROPE Framework Programme, H2020 Industrial Leadership, Ministero dell'Istruzione e del Merito
Openalex Percentile: Top 17%
Advanced MEMS and NEMS Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.