Short-term results of 360° selective laser trabeculoplasty in patients with failed deep sclerectomy

AIM: To evaluate the short-term results of 360° selective laser trabeculoplasty (SLT) in the treatment of patients with previously failed deep sclerectomy (DS). METHODS: Patients with open angle glaucoma with prior failed DS and insufficient postoperative intraocular pressure (IOP) control were enrolled. Preoperative and postoperative IOP were measured using a Goldmann applanation tonometer. One hundred non-overlapping laser shots were applied over 360°. IOP was measured before SLT and 1h after SLT. Follow-up was scheduled at the first week and at the first, third, and sixth months thereafter. RESULTS: =0.014). CONCLUSION: 360° SLT can be an effective complementary treatment after failed DS to decrease IOP and anti-glaucoma medications, thus improving patient compliance and tolerance.

Authors

Institutions

Publication Details

Journal
International Journal of Ophthalmology
Published
2026-04-15
DOI
https://doi.org/10.18240/ijo.2026.05.09
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Short-term results of 360° selective laser trabeculoplasty in patients with failed deep sclerectomy

Rasha Eltanamly, Rokaya Radwan, Maha A. Albadawi
International Journal of Ophthalmology
Glaucoma and retinal disorders
article

Short-term results of 360° selective laser trabeculoplasty in patients with failed deep sclerectomy

Rasha Eltanamly, Rokaya Radwan, Maha A. Albadawi
article en

Abstract

AIM: To evaluate the short-term results of 360° selective laser trabeculoplasty (SLT) in the treatment of patients with previously failed deep sclerectomy (DS). METHODS: Patients with open angle glaucoma with prior failed DS and insufficient postoperative intraocular pressure (IOP) control were enrolled. Preoperative and postoperative IOP were measured using a Goldmann applanation tonometer. One hundred non-overlapping laser shots were applied over 360°. IOP was measured before SLT and 1h after SLT. Follow-up was scheduled at the first week and at the first, third, and sixth months thereafter. RESULTS: =0.014). CONCLUSION: 360° SLT can be an effective complementary treatment after failed DS to decrease IOP and anti-glaucoma medications, thus improving patient compliance and tolerance.

International Journal of OphthalmologyVol. 19(5)
Cairo University (EG)
Good health and well-being
Openalex Percentile: Top 16%
Glaucoma and retinal disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.