Augmented reality for ultrasound-guided venipuncture: a pilot study on a simulated vascular access model

To evaluate the feasibility of a low-cost augmented reality (AR) workflow for ultrasound-guided venipuncture and whether AR visualisation is non-inferior to conventional monitor guidance in total procedure time while improving user experience. Real-time ultrasound video from a conventional scanner was captured via an HDMI-to-USB device, pre-processed with a Python/OpenCV pipeline, and streamed over Wi-Fi to a HoloLens 2 headset using WebSocket. A turkey-thigh model with an embedded fluid-filled catheter simulated a peripheral vein. One experienced implantation nurse performed 58 venipuncture attempts with standard monitor guidance and 58 with AR (monitor blanked during AR). Total procedure time (TPT) was recorded for each attempt, and a questionnaire assessed perceived difficulty, image quality, usability, reliability, and ergonomic comfort. With all data included, overall TPT was comparable between standard and AR guidance ([Formula: see text] s vs. [Formula: see text] s; [Formula: see text]). After excluding predefined outliers, overall TPT remained non-significantly lower with AR ([Formula: see text] s vs. [Formula: see text] s; [Formula: see text]); on day 2 the p-value decreased to 0.103 ([Formula: see text] s vs. [Formula: see text] s). Questionnaire responses favoured AR for gaze continuity, perceived coordination, usability, and ergonomic comfort, with acceptable image quality. AR-assisted ultrasound-guided venipuncture was feasible and did not add measurable temporal overhead for an expert operator, while improving perceived ergonomics. Larger, multi-operator clinical studies are needed to confirm performance effects and clinical impact.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Monitoring and Computing
Published
2026-04-15
DOI
https://doi.org/10.1007/s10877-026-01437-9
Primary Topic
Central Venous Catheters and Hemodialysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Augmented reality for ultrasound-guided venipuncture: a pilot study on a simulated vascular access model

Fulvio Pinelli, Leonardo Bocchi, Cosimo Aliani, Gianluca Villa et al.
Journal of Clinical Monitoring and Computing
Central Venous Catheters and Hemodialysis
article

Augmented reality for ultrasound-guided venipuncture: a pilot study on a simulated vascular access model

Fulvio Pinelli, Leonardo Bocchi, Cosimo Aliani, Gianluca Villa, Alberto Morelli, Simona Cristina Aiello, Stefano Romagnoli
article en

Abstract

To evaluate the feasibility of a low-cost augmented reality (AR) workflow for ultrasound-guided venipuncture and whether AR visualisation is non-inferior to conventional monitor guidance in total procedure time while improving user experience. Real-time ultrasound video from a conventional scanner was captured via an HDMI-to-USB device, pre-processed with a Python/OpenCV pipeline, and streamed over Wi-Fi to a HoloLens 2 headset using WebSocket. A turkey-thigh model with an embedded fluid-filled catheter simulated a peripheral vein. One experienced implantation nurse performed 58 venipuncture attempts with standard monitor guidance and 58 with AR (monitor blanked during AR). Total procedure time (TPT) was recorded for each attempt, and a questionnaire assessed perceived difficulty, image quality, usability, reliability, and ergonomic comfort. With all data included, overall TPT was comparable between standard and AR guidance ([Formula: see text] s vs. [Formula: see text] s; [Formula: see text]). After excluding predefined outliers, overall TPT remained non-significantly lower with AR ([Formula: see text] s vs. [Formula: see text] s; [Formula: see text]); on day 2 the p-value decreased to 0.103 ([Formula: see text] s vs. [Formula: see text] s). Questionnaire responses favoured AR for gaze continuity, perceived coordination, usability, and ergonomic comfort, with acceptable image quality. AR-assisted ultrasound-guided venipuncture was feasible and did not add measurable temporal overhead for an expert operator, while improving perceived ergonomics. Larger, multi-operator clinical studies are needed to confirm performance effects and clinical impact.

Journal of Clinical Monitoring and Computing
Azienda Ospedaliero-Universitaria Careggi (IT), University of Florence (IT)
Università degli Studi di Firenze
Openalex Percentile: Top 21%
Central Venous Catheters and Hemodialysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.