Impact of total stent length on long-term outcomes with different newer-generation drug-eluting stent designs in ST-segment elevation myocardial infarction: A subgroup analysis from the BIOSTEMI ES randomized trial

Background Longer total stent length (TSL) increases the risk of target lesion failure (TLF) in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention (PCI) with second-generation drug-eluting stents (DES). We aimed to assess the long-term impact of TSL on patient- and stent-related outcomes in STEMI patients treated with different newer-generation DES designs. Methods We performed a post hoc subgroup analysis of the BIOSTEMI Extended Survival randomized trial (NCT05484310). Patients undergoing primary PCI for STEMI were randomized to ultrathin-strut biodegradable-polymer sirolimus-eluting stents (BP-SES) or thin-strut durable-polymer everolimus-eluting stents (DP-EES) and categorized according to TSL implanted at the culprit site (≤40 mm vs. >40 mm). The device-oriented composite endpoint (TLF) was the composite of cardiac death, target-vessel (TV) myocardial reinfarction, or clinically indicated target lesion revascularization (TLR), and the patient-oriented composite endpoint (POCE) was the composite of all-cause death, any myocardial reinfarction, any revascularization, or any stroke, at 5 years. Results A total of 1,686 STEMI patients were included (mean age, 62.4 years; female, 23%; mean TSL, 33.8 mm), of whom 423 (25%) were treated with TSL >40 mm. At 5 years, TSL >40 mm was associated with a significantly higher risk of POCE compared with TSL ≤40 mm [31.7% vs. 27.4%; hazard ratio (HR), 1.30; 95% confidence interval (CI), 1.03-1.64; p=0.029], whereas no difference was observed in TLF. However, there was a significant interaction between DES type and TSL for TLF at 5 years. Among patients with TSL >40 mm, BP-SES were associated with a lower risk of TLF compared with DP-EES (7.3% vs. 17.1%; HR, 0.39; 95% CI, 0.21-0.74; p=0.004; p for interaction=0.032), a difference primarily driven by a lower rate of target vessel myocardial reinfarction. No significant differences between BP-SES and DP-EES were observed in patients with TSL ≤40 mm. After adjustment for multivessel treatment, increasing TSL with DP-EES, but not BP-SES, was independently associated with a higher risk of TLF (adjusted HR per 5-mm increase, 1.07; 95% CI, 1.02-1.11; p=0.003). Conclusion In STEMI patients treated with contemporary DES, TSL >40 mm was associated with an increased risk of patient-oriented, but not device-related, adverse outcomes at 5 years. Among patients requiring TSL >40 mm, ultrathin-strut BP-SES significantly reduced the risk of TLF compared with DP-EES, whereas no between-DES differences were observed in patients treated with TSL ≤40 mm.

Authors

Institutions

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2026-04-15
DOI
https://doi.org/10.48620/96971
Primary Topic
Coronary Interventions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of total stent length on long-term outcomes with different newer-generation drug-eluting stent designs in ST-segment elevation myocardial infarction: A subgroup analysis from the BIOSTEMI ES randomized trial

David J. Kurz, Johannes Rigger, Grégoire Girod, Sylvain Losdat et al.
Open Access CRIS of the University of Bern
Coronary Interventions and Diagnostics
article

Impact of total stent length on long-term outcomes with different newer-generation drug-eluting stent designs in ST-segment elevation myocardial infarction: A subgroup analysis from the BIOSTEMI ES randomized trial

David J. Kurz, Johannes Rigger, Grégoire Girod, Sylvain Losdat, Dik Heg, L Haegeli, Marco Roffi, Juan Eugenio Iglesias, Christoph Kaiser, Thomas Pilgrim, Stephan Windecker, Matthias Bossard, Olivier Muller, Stéphane Cook
article en

Abstract

Background Longer total stent length (TSL) increases the risk of target lesion failure (TLF) in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention (PCI) with second-generation drug-eluting stents (DES). We aimed to assess the long-term impact of TSL on patient- and stent-related outcomes in STEMI patients treated with different newer-generation DES designs. Methods We performed a post hoc subgroup analysis of the BIOSTEMI Extended Survival randomized trial (NCT05484310). Patients undergoing primary PCI for STEMI were randomized to ultrathin-strut biodegradable-polymer sirolimus-eluting stents (BP-SES) or thin-strut durable-polymer everolimus-eluting stents (DP-EES) and categorized according to TSL implanted at the culprit site (≤40 mm vs. >40 mm). The device-oriented composite endpoint (TLF) was the composite of cardiac death, target-vessel (TV) myocardial reinfarction, or clinically indicated target lesion revascularization (TLR), and the patient-oriented composite endpoint (POCE) was the composite of all-cause death, any myocardial reinfarction, any revascularization, or any stroke, at 5 years. Results A total of 1,686 STEMI patients were included (mean age, 62.4 years; female, 23%; mean TSL, 33.8 mm), of whom 423 (25%) were treated with TSL >40 mm. At 5 years, TSL >40 mm was associated with a significantly higher risk of POCE compared with TSL ≤40 mm [31.7% vs. 27.4%; hazard ratio (HR), 1.30; 95% confidence interval (CI), 1.03-1.64; p=0.029], whereas no difference was observed in TLF. However, there was a significant interaction between DES type and TSL for TLF at 5 years. Among patients with TSL >40 mm, BP-SES were associated with a lower risk of TLF compared with DP-EES (7.3% vs. 17.1%; HR, 0.39; 95% CI, 0.21-0.74; p=0.004; p for interaction=0.032), a difference primarily driven by a lower rate of target vessel myocardial reinfarction. No significant differences between BP-SES and DP-EES were observed in patients with TSL ≤40 mm. After adjustment for multivessel treatment, increasing TSL with DP-EES, but not BP-SES, was independently associated with a higher risk of TLF (adjusted HR per 5-mm increase, 1.07; 95% CI, 1.02-1.11; p=0.003). Conclusion In STEMI patients treated with contemporary DES, TSL >40 mm was associated with an increased risk of patient-oriented, but not device-related, adverse outcomes at 5 years. Among patients requiring TSL >40 mm, ultrathin-strut BP-SES significantly reduced the risk of TLF compared with DP-EES, whereas no between-DES differences were observed in patients treated with TSL ≤40 mm.

Open Access CRIS of the University of Bern
IST Research (US)
Good health and well-being
Openalex Percentile: Top 28%
Coronary Interventions and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.