Mechanistic Study on the Baseline Drift Phenomenon of Piezoelectric Pressure Sensors When Measuring Blast Waves

Piezoelectric pressure sensors are commonly used as blast wave pressure sensors in explosion testing. Accurate measurement of blast wave overpressure is of great significance. In explosion testing, piezoelectric pressure sensors exhibit a baseline drift phenomenon. This paper analyzes the mechanism of the baseline drift phenomenon observed in explosion testing through experiments and simulation, identifying the mechanism behind it. From an experimental perspective, it is determined that the thermal effect of light induces the baseline drift phenomenon. Furthermore, modeling and simulation of the piezoelectric pressure sensor using COMSOL 6.2 Multiphysics software confirms that the photothermal effect causes changes in the temperature field within the sensor's internal structure, which in turn brings the thermal stress. The thermal stress superimposes on the output of piezoelectric pressure sensors. This is the fundamental cause of the baseline drift phenomenon in piezoelectric pressure sensors. This research provides a crucial foundation for understanding the mechanisms by which explosions affect piezoelectric pressure sensors.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-04-15
DOI
https://doi.org/10.3390/s26082430
Primary Topic
Structural Response to Dynamic Loads
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mechanistic Study on the Baseline Drift Phenomenon of Piezoelectric Pressure Sensors When Measuring Blast Waves

Jun Yang, Zutang Wu, Qianqian Cheng, Jin Li et al.
Sensors
Structural Response to Dynamic Loads
article

Mechanistic Study on the Baseline Drift Phenomenon of Piezoelectric Pressure Sensors When Measuring Blast Waves

Jun Yang, Zutang Wu, Qianqian Cheng, Jin Li, Jie Zhu, Hailong Hui, Liqiang Chen
article en

Abstract

Piezoelectric pressure sensors are commonly used as blast wave pressure sensors in explosion testing. Accurate measurement of blast wave overpressure is of great significance. In explosion testing, piezoelectric pressure sensors exhibit a baseline drift phenomenon. This paper analyzes the mechanism of the baseline drift phenomenon observed in explosion testing through experiments and simulation, identifying the mechanism behind it. From an experimental perspective, it is determined that the thermal effect of light induces the baseline drift phenomenon. Furthermore, modeling and simulation of the piezoelectric pressure sensor using COMSOL 6.2 Multiphysics software confirms that the photothermal effect causes changes in the temperature field within the sensor's internal structure, which in turn brings the thermal stress. The thermal stress superimposes on the output of piezoelectric pressure sensors. This is the fundamental cause of the baseline drift phenomenon in piezoelectric pressure sensors. This research provides a crucial foundation for understanding the mechanisms by which explosions affect piezoelectric pressure sensors.

SensorsVol. 26(8)
Northwest Institute of Nuclear Technology (CN)
Openalex Percentile: Top 23%
Structural Response to Dynamic Loads
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.