Development of an AR application for radiation protection optimisation education of medical staff in x-ray fluoroscopy

Medical staff handling radiological equipment may be exposed to occupational radiation when assisting patients or performing fluoroscopy-guided procedures in radiological examinations. In this study, we developed a radiation protection education application using augmented reality (AR) to display the scattered radiation volume data during supine x-ray examinations, including x-ray fluoroscopy. This application allows real-time estimation of the scattered radiation distribution in the room and the radiation exposure of medical staff. The ratio of calculated values to measured values for scattered radiation distribution fell within the range of 0.8 to 1.2 at 18 evaluation points. The scattered radiation distribution was displayed using AR on an iPhone or iPad. Additionally, the application provided real-time displays of the doses to the eyes, neck, chest, abdomen, and fingers of recognised medical staff through body tracking. This application is easy to use regardless of location and serves as an effective tool for radiation protection education for medical staff.

Authors

Institutions

Publication Details

Journal
Annals of the ICRP
Published
2026-04-15
DOI
https://doi.org/10.1177/01466453251412000
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of an AR application for radiation protection optimisation education of medical staff in x-ray fluoroscopy

T. Fujibuchi, T. Yoshinaga, H. Arakawa
Annals of the ICRP
Radiation Dose and Imaging
article

Development of an AR application for radiation protection optimisation education of medical staff in x-ray fluoroscopy

T. Fujibuchi, T. Yoshinaga, H. Arakawa
article en

Abstract

Medical staff handling radiological equipment may be exposed to occupational radiation when assisting patients or performing fluoroscopy-guided procedures in radiological examinations. In this study, we developed a radiation protection education application using augmented reality (AR) to display the scattered radiation volume data during supine x-ray examinations, including x-ray fluoroscopy. This application allows real-time estimation of the scattered radiation distribution in the room and the radiation exposure of medical staff. The ratio of calculated values to measured values for scattered radiation distribution fell within the range of 0.8 to 1.2 at 18 evaluation points. The scattered radiation distribution was displayed using AR on an iPhone or iPad. Additionally, the application provided real-time displays of the doses to the eyes, neck, chest, abdomen, and fingers of recognised medical staff through body tracking. This application is easy to use regardless of location and serves as an effective tool for radiation protection education for medical staff.

Annals of the ICRP
Kyushu University (JP), Mirai Hospital (JP)
Quality Education
Openalex Percentile: Top 6%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.