A Study of Radiation Exposure and the Effects of Real-time Dosimetry System on Staff Safety in Neurointerventional Procedures

BACKGROUND AND PURPOSE: Neurointerventional procedures expose both patients and medical personnel to significant radiation, raising concerns about long-term health risks. This study investigated whether real-time radiation monitoring systems reduce occupational radiation doses and improve radiation protection behaviors among staff. MATERIALS AND METHODS: We conducted a retrospective and prospective cohort study at Prince of Songkla University Minimally Invasive Surgical-Interventional Radiology Center between October 2023 and July 2024. The study included 167 patients undergoing cerebral angiograms and 28 medical personnel (interventional neuroradiologists, nurses, andradiologic technologists). Patient radiation metrics (Air Kerma, Dose-Area Product, Fluoroscopy Time) were collected via Radimetrics™ software. Personnel doses were measured using Optically Stimulated Luminescence dosimeters, with real-time Personal Dose Meters (RaySafe i3) implemented from January 2024 providing immediate feedback during procedures. RESULTS: and Air Kerma of 129.19 mGy, with mean fluoroscopy time of 2.7 minutes; all values remained below Thai national standards. Among personnel, interventional neuroradiologists demonstrated significant dose reduction following real-time monitoring implementation. Personal dose equivalent Hp(10) decreased from 1.628 mSv in 2023 to 0.335 mSv in 2024, representing a 79.4% reduction (p = .01). Hp(0.07) and Hp(3) values decreased by 15.7% and 16.1%, respectively (p = .01). Real-time monitoring enhanced personnel aware of the radiation dose levels in the angiography suite increased from 42.9% to 85.7%, with protective equipment utilization and optimal positioning practices improving significantly. CONCLUSIONS: Implementation of real-time personal radiation dosimeters significantly reduced occupational radiation exposure during neurointerventional procedures, particularly for interventional neuroradiologists. This reduction was achieved through enhanced staff awareness and improved radiation protection behaviors without compromising patient care quality.

Authors

Institutions

Publication Details

Journal
American Journal of Neuroradiology
Published
2026-04-15
DOI
https://doi.org/10.3174/ajnr.a9353
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Study of Radiation Exposure and the Effects of Real-time Dosimetry System on Staff Safety in Neurointerventional Procedures

Anantaya Senkhaw, Withoon Upamai
American Journal of Neuroradiology
Radiation Dose and Imaging
article

A Study of Radiation Exposure and the Effects of Real-time Dosimetry System on Staff Safety in Neurointerventional Procedures

Anantaya Senkhaw, Withoon Upamai
article en

Abstract

BACKGROUND AND PURPOSE: Neurointerventional procedures expose both patients and medical personnel to significant radiation, raising concerns about long-term health risks. This study investigated whether real-time radiation monitoring systems reduce occupational radiation doses and improve radiation protection behaviors among staff. MATERIALS AND METHODS: We conducted a retrospective and prospective cohort study at Prince of Songkla University Minimally Invasive Surgical-Interventional Radiology Center between October 2023 and July 2024. The study included 167 patients undergoing cerebral angiograms and 28 medical personnel (interventional neuroradiologists, nurses, andradiologic technologists). Patient radiation metrics (Air Kerma, Dose-Area Product, Fluoroscopy Time) were collected via Radimetrics™ software. Personnel doses were measured using Optically Stimulated Luminescence dosimeters, with real-time Personal Dose Meters (RaySafe i3) implemented from January 2024 providing immediate feedback during procedures. RESULTS: and Air Kerma of 129.19 mGy, with mean fluoroscopy time of 2.7 minutes; all values remained below Thai national standards. Among personnel, interventional neuroradiologists demonstrated significant dose reduction following real-time monitoring implementation. Personal dose equivalent Hp(10) decreased from 1.628 mSv in 2023 to 0.335 mSv in 2024, representing a 79.4% reduction (p = .01). Hp(0.07) and Hp(3) values decreased by 15.7% and 16.1%, respectively (p = .01). Real-time monitoring enhanced personnel aware of the radiation dose levels in the angiography suite increased from 42.9% to 85.7%, with protective equipment utilization and optimal positioning practices improving significantly. CONCLUSIONS: Implementation of real-time personal radiation dosimeters significantly reduced occupational radiation exposure during neurointerventional procedures, particularly for interventional neuroradiologists. This reduction was achieved through enhanced staff awareness and improved radiation protection behaviors without compromising patient care quality.

American Journal of Neuroradiology
Prince of Songkla University (TH)
Good health and well-being
Openalex Percentile: Top 14%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Study of Radiation Exposure and the Effects of Real-time Dosimetry System on Staff Safety in Neurointerventional Procedures — Anantaya Senkhaw, Withoon Upamai · American Journal of Neuroradiology (2026) | TGRS Research Map | TGRS