Deterministic Acceptance Limits for Statistical Equivalence Testing in Hydrogen/Deuterium Exchange Mass Spectrometry

Hydrogen/Deuterium Exchange Mass Spectrometry (HDX-MS) is a unique, rapidly evolving technique that has been widely adopted for the characterization of the higher-order structure of proteins. Numerous statistical tools are available in the literature that can be used to identify statistically significant differences in the deuterium uptake values. Biopharmaceutical comparability studies, however, require evidence that two protein samples are highly similar and therefore necessitate a different statistical approach. Hageman et al. recently introduced an innovative HDX-MS equivalence testing method utilizing univariate two one-sided tests (TOST). The acceptance limits were established by the randomized resampling of eight replicate measurements of a reference protein. However, this approach can introduce a non-negligible level of variability in the acceptance limits when the same data set is reanalyzed. In the present study, we enhance this method by replacing the randomized resampling process with the systematic enumeration of all possible combinations of the reference data set, thus eliminating the resampling-induced variation. Because this approach incorporates all measurements, including replicate combinations with markedly elevated variability, it leads to higher acceptance limits. Therefore, we evaluated three strategies: robust outlier detection, a percentile-based method, and a partitioning approach to establish more stringent criteria and reduce patient risk. By applying the enhanced methods to data sets of three approved infliximab biosimilars and a partially deglycosylated NIST mAb used as a mock candidate biosimilar, we demonstrated correct classification of equivalent and nonequivalent samples, making the enhanced evaluation strategy well suited for regulatory comparability assessment.

Authors

Institutions

Publication Details

Journal
Journal of the American Society for Mass Spectrometry
Published
2026-04-15
DOI
https://doi.org/10.1021/jasms.6c00035
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Deterministic Acceptance Limits for Statistical Equivalence Testing in Hydrogen/Deuterium Exchange Mass Spectrometry

Peter Lenárt, Gergely Tóth, Kinga Komka, Viktor Háda et al.
Journal of the American Society for Mass Spectrometry
Mass Spectrometry Techniques and Applications
article

Deterministic Acceptance Limits for Statistical Equivalence Testing in Hydrogen/Deuterium Exchange Mass Spectrometry

Peter Lenárt, Gergely Tóth, Kinga Komka, Viktor Háda, Gitta Schlosser
article en

Abstract

Hydrogen/Deuterium Exchange Mass Spectrometry (HDX-MS) is a unique, rapidly evolving technique that has been widely adopted for the characterization of the higher-order structure of proteins. Numerous statistical tools are available in the literature that can be used to identify statistically significant differences in the deuterium uptake values. Biopharmaceutical comparability studies, however, require evidence that two protein samples are highly similar and therefore necessitate a different statistical approach. Hageman et al. recently introduced an innovative HDX-MS equivalence testing method utilizing univariate two one-sided tests (TOST). The acceptance limits were established by the randomized resampling of eight replicate measurements of a reference protein. However, this approach can introduce a non-negligible level of variability in the acceptance limits when the same data set is reanalyzed. In the present study, we enhance this method by replacing the randomized resampling process with the systematic enumeration of all possible combinations of the reference data set, thus eliminating the resampling-induced variation. Because this approach incorporates all measurements, including replicate combinations with markedly elevated variability, it leads to higher acceptance limits. Therefore, we evaluated three strategies: robust outlier detection, a percentile-based method, and a partitioning approach to establish more stringent criteria and reduce patient risk. By applying the enhanced methods to data sets of three approved infliximab biosimilars and a partially deglycosylated NIST mAb used as a mock candidate biosimilar, we demonstrated correct classification of equivalent and nonequivalent samples, making the enhanced evaluation strategy well suited for regulatory comparability assessment.

Journal of the American Society for Mass SpectrometryVol. 37(5)
Eötvös Loránd University (HU), Gedeon Richter (Hungary) (HU), Budapest University of Technology and Economics (HU)
Magyar Tudományos Akadémia, Richter Gedeon Talentum Alapítvány
Openalex Percentile: Top 27%
Mass Spectrometry Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.