Spectral Photon-Counting Detector CT for Comprehensive Evaluation of Carotid Plaque and Stenosis

BACKGROUND: Conventional energy-integrating detector (EID) CT is limited in differentiating soft-plaque components due to overlapping attenuation values and is frequently affected by calcification-related blooming artifacts that obscure the vessel lumen and may overestimate stenosis. Photon-counting detector CT (PCD-CT) can provide enhanced spatial resolution and spectral discrimination compared with conventional EID-CT, potentially improving carotid plaque characterization and mitigating artifact-related limitations. This study systematically evaluated image quality, plaque component attenuation, and stenosis visualization across spectral PCD-CT reconstructions. METHODS: We retrospectively included patients who underwent PCD-CT for carotid stenosis assessment. Four monoenergetic (ME 40, 55, 70, and 85 keV), PureLumen (PL), and virtual noncontrast (VNC) reconstructions were analyzed. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), edge sharpness, plaque area, degree of NASCET stenosis, and attenuation of plaque components (intraplaque hemorrhage, lipid-rich necrotic core, fibrotic tissue, calcification) were compared using repeated-measures ANOVA with Bonferroni correction. RESULTS: Our study included 27 patients (16 men, age: 74.5±9.1 y) with 50 plaques. CNR, SNR, and noise decreased with increasing ME levels ( P <0.001). PL yielded CNR and sharpness comparable to ME55, whereas VNC exhibited a near-zero lumen signal. Stenosis remained consistent across ME reconstructions (44% to 45%, P =1.00), but significantly reduced for PL (38%, P <0.001). Lower-energy reconstructions (ME40/ME55) improved the separation of attenuation values between the lumen and the various plaque components. CONCLUSION: Low-energy PCD-CT reconstructions enhance CNR and sharpness while maintaining consistent plaque and stenosis measurements. The PL algorithm may improve the assessment of calcified plaques, where conventional reconstructions may overestimate stenosis. PCD-CT shows promise for advanced plaque composition evaluation, but further validation against MRI and histology is warranted.

Authors

Institutions

Publication Details

Journal
Investigative Radiology
Published
2026-04-15
DOI
https://doi.org/10.1097/rli.0000000000001291
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Spectral Photon-Counting Detector CT for Comprehensive Evaluation of Carotid Plaque and Stenosis

M. Eline Kooi, Juul Bierens, Luc J.M. Smits, Alida A. Postma et al.
Investigative Radiology
Advanced X-ray and CT Imaging
article

Spectral Photon-Counting Detector CT for Comprehensive Evaluation of Carotid Plaque and Stenosis

M. Eline Kooi, Juul Bierens, Luc J.M. Smits, Alida A. Postma, Florentina M.E. Pinckaers, Jelske Kuijpers, Thomas Flohr, Robert J. van Oostenbrugge, Luca Saba
article en

Abstract

BACKGROUND: Conventional energy-integrating detector (EID) CT is limited in differentiating soft-plaque components due to overlapping attenuation values and is frequently affected by calcification-related blooming artifacts that obscure the vessel lumen and may overestimate stenosis. Photon-counting detector CT (PCD-CT) can provide enhanced spatial resolution and spectral discrimination compared with conventional EID-CT, potentially improving carotid plaque characterization and mitigating artifact-related limitations. This study systematically evaluated image quality, plaque component attenuation, and stenosis visualization across spectral PCD-CT reconstructions. METHODS: We retrospectively included patients who underwent PCD-CT for carotid stenosis assessment. Four monoenergetic (ME 40, 55, 70, and 85 keV), PureLumen (PL), and virtual noncontrast (VNC) reconstructions were analyzed. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), edge sharpness, plaque area, degree of NASCET stenosis, and attenuation of plaque components (intraplaque hemorrhage, lipid-rich necrotic core, fibrotic tissue, calcification) were compared using repeated-measures ANOVA with Bonferroni correction. RESULTS: Our study included 27 patients (16 men, age: 74.5±9.1 y) with 50 plaques. CNR, SNR, and noise decreased with increasing ME levels ( P <0.001). PL yielded CNR and sharpness comparable to ME55, whereas VNC exhibited a near-zero lumen signal. Stenosis remained consistent across ME reconstructions (44% to 45%, P =1.00), but significantly reduced for PL (38%, P <0.001). Lower-energy reconstructions (ME40/ME55) improved the separation of attenuation values between the lumen and the various plaque components. CONCLUSION: Low-energy PCD-CT reconstructions enhance CNR and sharpness while maintaining consistent plaque and stenosis measurements. The PL algorithm may improve the assessment of calcified plaques, where conventional reconstructions may overestimate stenosis. PCD-CT shows promise for advanced plaque composition evaluation, but further validation against MRI and histology is warranted.

Investigative Radiology
Maastricht University (NL)
Affordable and clean energy
Openalex Percentile: Top 20%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.