Criterion for the idling failure state of the upstream exhaust vent in inclined tunnel fires with ceiling central smoke extraction

Compared with horizontal tunnels, the upstream exhaust vent in inclined tunnels under a centralized ceiling smoke exhaust system is more likely to operate in an idling failure state (IFS), where due to the smoke layer failing to reach beneath the vent, it thereby extracts only fresh air while capturing no smoke, which significantly reduces system performance. Accordingly, this study systematically investigated the smoke back-layering length and the operational status of the upstream exhaust vent in inclined tunnels with a centralized ceiling exhaust system, through theoretical analysis, numerical simulation, and small-scale experiments. The results show that a larger tunnel slope or a greater distance from the downstream exhaust vent to the tunnel portal leads to a shorter back-layering length, which can gradually cause the upstream exhaust vent to enter an IFS. Similarly, a greater distance between the fire source and the upstream vent results in a longer back-layering length, but may also eventually lead to an IFS. Based on the analysis of influencing factors, a predictive correlation for the dimensionless upstream smoke back-layering length was established, incorporating the aforementioned three key parameters. Furthermore, a criterion for identifying the IFS of the upstream vent was proposed. Both the predictions from the correlation and the determinations from the criterion were validated against simulation results, showing that all predictions fall within an acceptable range.

Authors

Institutions

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2026-04-15
DOI
https://doi.org/10.1016/j.csite.2026.108061
Primary Topic
Fire dynamics and safety research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Criterion for the idling failure state of the upstream exhaust vent in inclined tunnel fires with ceiling central smoke extraction

Zhenpeng Bai, Hai Yao, Zeqi Wu, Tao Du et al.
Case Studies in Thermal Engineering
Fire dynamics and safety research
article

Criterion for the idling failure state of the upstream exhaust vent in inclined tunnel fires with ceiling central smoke extraction

Zhenpeng Bai, Hai Yao, Zeqi Wu, Tao Du, Yingli Liu, Yang Liu
article en

Abstract

Compared with horizontal tunnels, the upstream exhaust vent in inclined tunnels under a centralized ceiling smoke exhaust system is more likely to operate in an idling failure state (IFS), where due to the smoke layer failing to reach beneath the vent, it thereby extracts only fresh air while capturing no smoke, which significantly reduces system performance. Accordingly, this study systematically investigated the smoke back-layering length and the operational status of the upstream exhaust vent in inclined tunnels with a centralized ceiling exhaust system, through theoretical analysis, numerical simulation, and small-scale experiments. The results show that a larger tunnel slope or a greater distance from the downstream exhaust vent to the tunnel portal leads to a shorter back-layering length, which can gradually cause the upstream exhaust vent to enter an IFS. Similarly, a greater distance between the fire source and the upstream vent results in a longer back-layering length, but may also eventually lead to an IFS. Based on the analysis of influencing factors, a predictive correlation for the dimensionless upstream smoke back-layering length was established, incorporating the aforementioned three key parameters. Furthermore, a criterion for identifying the IFS of the upstream vent was proposed. Both the predictions from the correlation and the determinations from the criterion were validated against simulation results, showing that all predictions fall within an acceptable range.

Case Studies in Thermal EngineeringVol. 82
Zhengzhou University of Light Industry (CN), Chang'an University (CN)
Zhengzhou University
Openalex Percentile: Top 26%
Fire dynamics and safety research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Criterion for the idling failure state of the upstream exhaust vent in inclined tunnel fires with ceiling central smoke extraction — Zhenpeng Bai, Hai Yao, et al. · Case Studies in Thermal Engineering (2026) | TGRS Research Map | TGRS