Case Report: Optimizing ICU management of sickle cell crisis: the impact of bedside ultrasound on clinical decision-making

Introduction: Acute chest syndrome (ACS) is a leading cause of mortality in Sickle Cell Disease (SCD), often characterized by rapid respiratory decline and acute pulmonary hypertension (PH). While exchange transfusion is the standard of care for severe cases, delayed access to hemoglobin (Hb) electrophoresis often hinders real-time monitoring of therapeutic efficacy. We propose that POCUS guided assessments of pulmonary arterial pressures via tricuspid regurgitation jet velocities can serve as a real-time hemodynamic tool to direct serial exchange transfusions thereby preventing right heart failure and mortality in severe acute chest syndrome. Case presentation: A 20-year-old male patient with HbSS (baseline HbS 28.7%, on hydroxyurea) presented with shortness of breath, severe hip/back pain and acute hemolysis (Hb 8.3 g/dL, bilirubin 7.4 mg/dL, LDH 484 U/L). Despite treatment for ACS and an initial exchange transfusion, his oxygen requirements escalated from simple nasal cannula to high-flow nasal cannula. Repeated imaging showed worsening infiltrates, and Point-of-Care Ultrasound (POCUS) revealed acute PH (TR jet velocity > 4 m/s). Management and outcome: Following the second exchange transfusion, the patient's tachycardia, dyspnea, and oxygen requirements rapidly improved. Follow-up Point-of-Care Ultrasound (POCUS) demonstrated an improved and now trace tricuspid regurgitation. Subsequent electrophoresis confirmed the first exchange only reduced HbS to 49%, while the second achieved a therapeutic level of 20.9% (recommended target HbS of <30% by American Society of Hematology). Discussion/conclusion: < 0.001). Given that POCUS provides high diagnostic accuracy (AUC 0.87), it may be utilized as a real-time hemodynamic monitor to guide the necessity of serial exchange transfusions in the absence of immediate HbS% quantification. In severe ACS, achieving a target HbS ≤ 30% is vital, and bedside echocardiography may identify patients requiring immediate repeat exchange transfusion to prevent right heart failure and death.

Authors

Institutions

Publication Details

Journal
Frontiers in Medicine
Published
2026-04-15
DOI
https://doi.org/10.3389/fmed.2026.1804466
Primary Topic
Ultrasound in Clinical Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Case Report: Optimizing ICU management of sickle cell crisis: the impact of bedside ultrasound on clinical decision-making

Devanshi Mehta
Frontiers in Medicine
Ultrasound in Clinical Applications
article

Case Report: Optimizing ICU management of sickle cell crisis: the impact of bedside ultrasound on clinical decision-making

Devanshi Mehta
article en

Abstract

Introduction: Acute chest syndrome (ACS) is a leading cause of mortality in Sickle Cell Disease (SCD), often characterized by rapid respiratory decline and acute pulmonary hypertension (PH). While exchange transfusion is the standard of care for severe cases, delayed access to hemoglobin (Hb) electrophoresis often hinders real-time monitoring of therapeutic efficacy. We propose that POCUS guided assessments of pulmonary arterial pressures via tricuspid regurgitation jet velocities can serve as a real-time hemodynamic tool to direct serial exchange transfusions thereby preventing right heart failure and mortality in severe acute chest syndrome. Case presentation: A 20-year-old male patient with HbSS (baseline HbS 28.7%, on hydroxyurea) presented with shortness of breath, severe hip/back pain and acute hemolysis (Hb 8.3 g/dL, bilirubin 7.4 mg/dL, LDH 484 U/L). Despite treatment for ACS and an initial exchange transfusion, his oxygen requirements escalated from simple nasal cannula to high-flow nasal cannula. Repeated imaging showed worsening infiltrates, and Point-of-Care Ultrasound (POCUS) revealed acute PH (TR jet velocity > 4 m/s). Management and outcome: Following the second exchange transfusion, the patient's tachycardia, dyspnea, and oxygen requirements rapidly improved. Follow-up Point-of-Care Ultrasound (POCUS) demonstrated an improved and now trace tricuspid regurgitation. Subsequent electrophoresis confirmed the first exchange only reduced HbS to 49%, while the second achieved a therapeutic level of 20.9% (recommended target HbS of <30% by American Society of Hematology). Discussion/conclusion: < 0.001). Given that POCUS provides high diagnostic accuracy (AUC 0.87), it may be utilized as a real-time hemodynamic monitor to guide the necessity of serial exchange transfusions in the absence of immediate HbS% quantification. In severe ACS, achieving a target HbS ≤ 30% is vital, and bedside echocardiography may identify patients requiring immediate repeat exchange transfusion to prevent right heart failure and death.

Frontiers in MedicineVol. 13
The University of Texas at Tyler (US), The University of Texas Health Science Center at Tyler (US)
Good health and well-being
Openalex Percentile: Top 21%
Ultrasound in Clinical Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.