OpenThermal: A Free-Use Reference Design for Passive City-Scale Cooling and Power Using CNF Thermosiphon Towers v1.2

Urban heat islands and data center cooling represent >5% of global electricity demand and drive peak grid emissions. We present a fully open hardware reference design, the Planetary Thermal Siphon (PTS), that converts low-grade waste heat into three products: 1) passive cooling, 2) 24/7 carbon-free electricity, and 3) atmospheric water. The system uses a hub-and-spoke model: dimpled carbon nanofibre (CNF) ground mats collect heat in cities and transfer it via insulated, subterranean CNF pipes to 300–350 m CNF towers located on low hills outside flight paths. The 2.7–3.8 °C natural lapse rate drives a liquid thermosiphon, rejecting heat to the upper atmosphere. Electricity is co-generated by CNF solar skins with photon up-conversion (~35% efficiency) and Seebeck modules along the thermal gradient. Condensed water is harvested at altitude for irrigation and fire breaks. Techno-economic optimization shows peak ROI at 300–350 m tower height when sited on natural low hills 20–50 km from load centers. At 300–350 m, each tower rejects 8–15 MW of heat and generates 0.75–1.05 MW average continuous power. CAPEX is ~$10.3M per tower with 10–12 yr payback, followed by 80+ years service life. Because CNF is synthesized from biomass, each tower sequesters 3–8 kt CO2 in long-lived structure, enabling gigatonne-scale negative emissions if deployed globally. All designs, calculations, and test data are released under CERN Open Hardware Licence v2 – Strongly Reciprocal (CERN-OHL-S v2). We solicit replication of the 3 m benchtop demonstrator and invite peer review of the pressure-break and safety analyses. Keywords: carbon nanofibre, thermosiphon, urban heat island, data center cooling, PUE, open hardware, negative emissions, passive cooling, atmospheric water harvesting

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-04-16
DOI
https://doi.org/10.5281/zenodo.19568407
Primary Topic
Thermal Radiation and Cooling Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

OpenThermal: A Free-Use Reference Design for Passive City-Scale Cooling and Power Using CNF Thermosiphon Towers v1.2

David Seagal
Zenodo (CERN European Organization for Nuclear Research)
Thermal Radiation and Cooling Technologies
article

OpenThermal: A Free-Use Reference Design for Passive City-Scale Cooling and Power Using CNF Thermosiphon Towers v1.2

David Seagal
article en

Abstract

Urban heat islands and data center cooling represent >5% of global electricity demand and drive peak grid emissions. We present a fully open hardware reference design, the Planetary Thermal Siphon (PTS), that converts low-grade waste heat into three products: 1) passive cooling, 2) 24/7 carbon-free electricity, and 3) atmospheric water. The system uses a hub-and-spoke model: dimpled carbon nanofibre (CNF) ground mats collect heat in cities and transfer it via insulated, subterranean CNF pipes to 300–350 m CNF towers located on low hills outside flight paths. The 2.7–3.8 °C natural lapse rate drives a liquid thermosiphon, rejecting heat to the upper atmosphere. Electricity is co-generated by CNF solar skins with photon up-conversion (~35% efficiency) and Seebeck modules along the thermal gradient. Condensed water is harvested at altitude for irrigation and fire breaks. Techno-economic optimization shows peak ROI at 300–350 m tower height when sited on natural low hills 20–50 km from load centers. At 300–350 m, each tower rejects 8–15 MW of heat and generates 0.75–1.05 MW average continuous power. CAPEX is ~$10.3M per tower with 10–12 yr payback, followed by 80+ years service life. Because CNF is synthesized from biomass, each tower sequesters 3–8 kt CO2 in long-lived structure, enabling gigatonne-scale negative emissions if deployed globally. All designs, calculations, and test data are released under CERN Open Hardware Licence v2 – Strongly Reciprocal (CERN-OHL-S v2). We solicit replication of the 3 m benchtop demonstrator and invite peer review of the pressure-break and safety analyses. Keywords: carbon nanofibre, thermosiphon, urban heat island, data center cooling, PUE, open hardware, negative emissions, passive cooling, atmospheric water harvesting

Zenodo (CERN European Organization for Nuclear Research)
Sustainable cities and communities
Openalex Percentile: Top 8%
Thermal Radiation and Cooling Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.