A New Potential Biomarker for Strychnine Misuse in Human Urine Using Quadrupole‐Orbitrap LC–MS/MS

In this study, we investigate the metabolic profile of strychnine in human urine following controlled administration using liquid chromatography-quadrupole-Orbitrap mass spectrometry. A total of 25 metabolites were characterized and identified. These included 21 previously unreported and 4 previously reported metabolites. Four unreported metabolic pathways were discovered, namely, reduction, methylation, glycosylation, and glucuronidation. Among these, hydroxylation was identified as the major metabolic pathway. The detection windows in the urine for all 25 metabolites were compared with that of the parent drug. Metabolite S10 (2,3-dimethoxy-strychnine) was proposed as a novel potential biomarker for strychnine misuse, rather than strychnine itself, due to its longer detection time and higher number of strychnine-positive time points (exceeding 50 ng/mL in human urine) compared to the parent compound after oral administration. The identification of S10 extends the detection window and offers critical insights for doping control applications.

Authors

Institutions

Publication Details

Journal
Rapid Communications in Mass Spectrometry
Published
2026-04-15
DOI
https://doi.org/10.1002/rcm.70079
Primary Topic
Metabolomics and Mass Spectrometry Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A New Potential Biomarker for Strychnine Misuse in Human Urine Using Quadrupole‐Orbitrap LC–MS/MS

Xiaopei Wu, Qiaoling Fei, 陆江海, Xuxiao Zhao et al.
Rapid Communications in Mass Spectrometry
Metabolomics and Mass Spectrometry Studies
article

A New Potential Biomarker for Strychnine Misuse in Human Urine Using Quadrupole‐Orbitrap LC–MS/MS

Xiaopei Wu, Qiaoling Fei, 陆江海, Xuxiao Zhao, Jiarui Wang, Jing Jing, Yang Liu
article en

Abstract

In this study, we investigate the metabolic profile of strychnine in human urine following controlled administration using liquid chromatography-quadrupole-Orbitrap mass spectrometry. A total of 25 metabolites were characterized and identified. These included 21 previously unreported and 4 previously reported metabolites. Four unreported metabolic pathways were discovered, namely, reduction, methylation, glycosylation, and glucuronidation. Among these, hydroxylation was identified as the major metabolic pathway. The detection windows in the urine for all 25 metabolites were compared with that of the parent drug. Metabolite S10 (2,3-dimethoxy-strychnine) was proposed as a novel potential biomarker for strychnine misuse, rather than strychnine itself, due to its longer detection time and higher number of strychnine-positive time points (exceeding 50 ng/mL in human urine) compared to the parent compound after oral administration. The identification of S10 extends the detection window and offers critical insights for doping control applications.

Rapid Communications in Mass SpectrometryVol. 40(13)
Peking University (CN), China Anti-Doping Agency (CN), Peking University Third Hospital (CN)
Good health and well-being
Openalex Percentile: Top 14%
Metabolomics and Mass Spectrometry Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A New Potential Biomarker for Strychnine Misuse in Human Urine Using Quadrupole‐Orbitrap LC–MS/MS — Xiaopei Wu, Qiaoling Fei, et al. · Rapid Communications in Mass Spectrometry (2026) | TGRS Research Map | TGRS