Sub-glottic Diameter Measured by Ultrasonography Predicts Outer Diameter of the Clinically Best Fit Endotracheal Tube in Infants Undergoing Pediatric Cardiac Surgery

BACKGROUND: Tracheal intubation with an oversized endotracheal tube (ETT) in a pediatric patient can lead to serious complications following extubation, including stridor, hoarseness, difficulty in breathing, increased work of breathing, respiratory failure, cardiac failure, and reintubation. Whereas undersized ETT may lead to erratic delivery of preset tidal volume during mechanical ventilation and increase the risk of aspiration of gastric contents. This study investigates the correlation between ultrasound measured subglottic airway diameter and ETT size selected by the anesthesiologists in infants undergoing cardiac surgery. MATERIALS AND METHODS: We measured the subglottic airway diameter in sniffing position with a 25 mm linear high frequency hockey stick transducer using ultrasonography machine and compared it to the ETT size selected by the anesthesiologist. We analyzed the agreement between the two methods. RESULTS: One hundred and three infants undergoing cardiac surgery were included. The median age of the infants were 30 days (interquartile range 19-90 days). The anesthesiologist's ETT size choice matched ultrasonography (USG)-measured subglottic diameter in all patients, with 90 receiving 3.5 mm ID and 13 receiving 4.0 mm ID ETTs. Upsizing of the ETT due to air leak was not required in any patient. A significant correlation was found between USG-measured ETT size and the anesthesiologist's choice of clinically best-fit ETT. CONCLUSIONS: Subglottic diameter measured by USG reliably predict outer diameter of the ETT size in infants undergoing cardiac surgery. The finding is particularly valuable in low-volume centers where anesthesiologists may have limited experience with pediatric cardiac surgery.

Authors

Institutions

Publication Details

Journal
Annals of Cardiac Anaesthesia
Published
2026-04-01
DOI
https://doi.org/10.4103/aca.aca_189_25
Citations
1
Primary Topic
Tracheal and airway disorders
Type
article
Field-Weighted Citation Impact
22.41
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sub-glottic Diameter Measured by Ultrasonography Predicts Outer Diameter of the Clinically Best Fit Endotracheal Tube in Infants Undergoing Pediatric Cardiac Surgery

Praveen Kumar Neema, Jessin P. Jayasankar, L. Sai Sudha
1 citations
Annals of Cardiac Anaesthesia
Tracheal and airway disorders
22.41
article

Sub-glottic Diameter Measured by Ultrasonography Predicts Outer Diameter of the Clinically Best Fit Endotracheal Tube in Infants Undergoing Pediatric Cardiac Surgery

Praveen Kumar Neema, Jessin P. Jayasankar, L. Sai Sudha
article en
1 citations

Abstract

BACKGROUND: Tracheal intubation with an oversized endotracheal tube (ETT) in a pediatric patient can lead to serious complications following extubation, including stridor, hoarseness, difficulty in breathing, increased work of breathing, respiratory failure, cardiac failure, and reintubation. Whereas undersized ETT may lead to erratic delivery of preset tidal volume during mechanical ventilation and increase the risk of aspiration of gastric contents. This study investigates the correlation between ultrasound measured subglottic airway diameter and ETT size selected by the anesthesiologists in infants undergoing cardiac surgery. MATERIALS AND METHODS: We measured the subglottic airway diameter in sniffing position with a 25 mm linear high frequency hockey stick transducer using ultrasonography machine and compared it to the ETT size selected by the anesthesiologist. We analyzed the agreement between the two methods. RESULTS: One hundred and three infants undergoing cardiac surgery were included. The median age of the infants were 30 days (interquartile range 19-90 days). The anesthesiologist's ETT size choice matched ultrasonography (USG)-measured subglottic diameter in all patients, with 90 receiving 3.5 mm ID and 13 receiving 4.0 mm ID ETTs. Upsizing of the ETT due to air leak was not required in any patient. A significant correlation was found between USG-measured ETT size and the anesthesiologist's choice of clinically best-fit ETT. CONCLUSIONS: Subglottic diameter measured by USG reliably predict outer diameter of the ETT size in infants undergoing cardiac surgery. The finding is particularly valuable in low-volume centers where anesthesiologists may have limited experience with pediatric cardiac surgery.

Annals of Cardiac AnaesthesiaVol. 29(2)
Amrita Institute of Medical Sciences and Research Centre (IN), Dubai Hospital (AE)
Openalex Percentile: Top 1%
Tracheal and airway disorders
22.41
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.