A nested PCR-based point-of-care multiplex test for detection of bacterial pathogens in cerebrospinal fluids

Objective: (GAS) in cerebrospinal fluid (CSF), achieving an automated "sample-in, result-out" workflow. Method: The sensitivity of the mOTN-PCR was assessed using recombinant plasmids, and its specificity was evaluated using common pathogens associated with CSF infections. Simulated CSF samples were prepared using both manual nucleic acid extraction and fully automated nucleic acid extraction (POCT instrument), and then detected in parallel by mOTN-PCR and conventional real-time PCR. The clinical performance of the mOTN-PCR-POCT assay was further evaluated using 109 clinical samples (36 clinical CSF samples and 73 non-CSF clinical samples), and compared with the manual nucleic acid extraction followed by the conventional real-time PCR method. Results: The mOTN-PCR achieved detection limits (LOD) of 5, 10, and 10 copies/μL for SPN, GBS, and GAS plasmids, respectively, with no cross-reactivity. In simulated CSF samples, the LODs were 20, 10, and 20 CFU/mL for SPN, GBS, and GAS, respectively, using manual extraction, within 4 hours. The mOTN-PCR-POCT method consistently detected all three pathogens at 20 CFU/mL, reducing total testing time to approximately 2 hours. Clinical sample testing revealed that the mOTN-PCR-POCT identified three additional positives in samples previously deemed negative by conventional real-time PCR, demonstrating superior detection capability and a more streamlined operational workflow of the mOTN-PCR-POCT. Conclusion: The mOTN-PCR-POCT was demonstrated to be simple to operate, requires no culture, and enables rapid, highly sensitive detection of SPN, GBS, and GAS in CSF.

Authors

Institutions

Publication Details

Journal
Frontiers in Cellular and Infection Microbiology
Published
2026-04-14
DOI
https://doi.org/10.3389/fcimb.2026.1781397
Primary Topic
Bacterial Identification and Susceptibility Testing
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A nested PCR-based point-of-care multiplex test for detection of bacterial pathogens in cerebrospinal fluids

Mengchuan Zhao, Zhishan Feng, Ying Wang, Pei Zhao et al.
Frontiers in Cellular and Infection Microbiology
Bacterial Identification and Susceptibility Testing
article

A nested PCR-based point-of-care multiplex test for detection of bacterial pathogens in cerebrospinal fluids

Mengchuan Zhao, Zhishan Feng, Ying Wang, Pei Zhao, Xingyu Liu, Juntao Meng, Yi-Xiang Wang, Duoxiao Zhang, He Tan, Pai Pang, Yanqing Tie, Shijue Gao, Xinxin Shen, Jianing Wu, Shihao Jiao, Zhiqiang Han, Xuejun Ma, Zijin Zhao
article en

Abstract

Objective: (GAS) in cerebrospinal fluid (CSF), achieving an automated "sample-in, result-out" workflow. Method: The sensitivity of the mOTN-PCR was assessed using recombinant plasmids, and its specificity was evaluated using common pathogens associated with CSF infections. Simulated CSF samples were prepared using both manual nucleic acid extraction and fully automated nucleic acid extraction (POCT instrument), and then detected in parallel by mOTN-PCR and conventional real-time PCR. The clinical performance of the mOTN-PCR-POCT assay was further evaluated using 109 clinical samples (36 clinical CSF samples and 73 non-CSF clinical samples), and compared with the manual nucleic acid extraction followed by the conventional real-time PCR method. Results: The mOTN-PCR achieved detection limits (LOD) of 5, 10, and 10 copies/μL for SPN, GBS, and GAS plasmids, respectively, with no cross-reactivity. In simulated CSF samples, the LODs were 20, 10, and 20 CFU/mL for SPN, GBS, and GAS, respectively, using manual extraction, within 4 hours. The mOTN-PCR-POCT method consistently detected all three pathogens at 20 CFU/mL, reducing total testing time to approximately 2 hours. Clinical sample testing revealed that the mOTN-PCR-POCT identified three additional positives in samples previously deemed negative by conventional real-time PCR, demonstrating superior detection capability and a more streamlined operational workflow of the mOTN-PCR-POCT. Conclusion: The mOTN-PCR-POCT was demonstrated to be simple to operate, requires no culture, and enables rapid, highly sensitive detection of SPN, GBS, and GAS in CSF.

Frontiers in Cellular and Infection MicrobiologyVol. 16
Hebei Medical University (CN), North China University of Science and Technology (CN), Hebei North University (CN), Hebei General Hospital (CN), National Institute for Viral Disease Control and Prevention (CN), Center for Clinical Research (United States) (US)
Openalex Percentile: Top 24%
Bacterial Identification and Susceptibility Testing
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.