Invisible shield: Sprayable supramolecular antimicrobial microscale films for preventing wound and medical device infections

Abstract Wound and device-associated infections remain difficult to eradicate because biofilms block host immunity and antibiotics, accelerating chronicity and resistance. Here, we present a portable, low-cost dual-syringe spray that deposits an ultra-thin, self-assembling antimicrobial film directly on wounds and implant surfaces. The device co-delivers oppositely charged hyaluronic acid (HA) and a cationic antimicrobial peptide (polyarginine, PAR30), which rapidly form a conformal nanometric polyelectrolyte complex at the tissue-material interface. Molecular dynamics simulation revealed pronounced positional heterogeneity within the PAR30/HA complex and identified an N-terminal arginine as a dominant interaction hotspot. The resulting coating adheres to diverse substrates, kills bacteria on contact, prevents biofilm formation, and sustains antimicrobial efficacy. Across vitro assays and murine wound infection models, treatment produced 4 to 5 log reductions in bacterial burden against methicillin-resistant Staphylococcus aureus and Gram-negative pathogens, including Pseudomonas aeruginosa and Escherichia coli . The formulation is biocompatible, did not increase cutaneous inflammation or IL-6 levels in vivo , and reduced post-surgical pain and motor deficits in a mouse incision model. To our knowledge, this is the first antimicrobial treatment system applicable to both tissues and medical devices. Developed under a safe-and-sustainable-by-design approach, this technology combines biocompatible components, nanometric coating for minimal material use, and a simple syringe-based delivery device, offering a scalable, antibiotic-free strategy for wound care and medical device infection prevention. Graphical abstract

Authors

Institutions

Publication Details

Journal
bioRxiv (Cold Spring Harbor Laboratory)
Published
2026-04-14
DOI
https://doi.org/10.64898/2026.04.10.717441
Primary Topic
Wound Healing and Treatments
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Invisible shield: Sprayable supramolecular antimicrobial microscale films for preventing wound and medical device infections

Thibaut Soubrié, Skander Hathroubi, Philipp Meier, Noémie Willem et al.
bioRxiv (Cold Spring Harbor Laboratory)
Wound Healing and Treatments
article

Invisible shield: Sprayable supramolecular antimicrobial microscale films for preventing wound and medical device infections

Thibaut Soubrié, Skander Hathroubi, Philipp Meier, Noémie Willem, Sarah Jester, Lauriane Petit, Giacomo Reina, David Grossin, Abdessalem Rekiki, Nihal Engin Vrana, Aurore Gaudin, Philippe Lavall�e, Christophe Drouet, Agnès Dupret‐Bories, Xavier Wurtz, Baptiste Letellier, Marjan Safarzadeh, Yijie Li, Derry Mercer, Ophelie Heck, Cynthia Calligaro, Bernd Nowack, Lucie Lieu, Peter Wick, Merve Tunali, Altan Demircan
article en

Abstract

Abstract Wound and device-associated infections remain difficult to eradicate because biofilms block host immunity and antibiotics, accelerating chronicity and resistance. Here, we present a portable, low-cost dual-syringe spray that deposits an ultra-thin, self-assembling antimicrobial film directly on wounds and implant surfaces. The device co-delivers oppositely charged hyaluronic acid (HA) and a cationic antimicrobial peptide (polyarginine, PAR30), which rapidly form a conformal nanometric polyelectrolyte complex at the tissue-material interface. Molecular dynamics simulation revealed pronounced positional heterogeneity within the PAR30/HA complex and identified an N-terminal arginine as a dominant interaction hotspot. The resulting coating adheres to diverse substrates, kills bacteria on contact, prevents biofilm formation, and sustains antimicrobial efficacy. Across vitro assays and murine wound infection models, treatment produced 4 to 5 log reductions in bacterial burden against methicillin-resistant Staphylococcus aureus and Gram-negative pathogens, including Pseudomonas aeruginosa and Escherichia coli . The formulation is biocompatible, did not increase cutaneous inflammation or IL-6 levels in vivo , and reduced post-surgical pain and motor deficits in a mouse incision model. To our knowledge, this is the first antimicrobial treatment system applicable to both tissues and medical devices. Developed under a safe-and-sustainable-by-design approach, this technology combines biocompatible components, nanometric coating for minimal material use, and a simple syringe-based delivery device, offering a scalable, antibiotic-free strategy for wound care and medical device infection prevention. Graphical abstract

bioRxiv (Cold Spring Harbor Laboratory)
Centre National de la Recherche Scientifique (FR), Inserm (FR), Université Fédérale de Toulouse Midi-Pyrénées (FR), Institut des Neurosciences Cellulaires et Intégratives (FR), Hôpital Larrey (FR), Da Volterra (France) (FR), Centre Interuniversitaire de Recherche et d’Ingénierie des Matériaux (FR), BIOASTER (FR), Université de Strasbourg (FR), Swiss Federal Laboratories for Materials Science and Technology (CH)
European Commission, HORIZON EUROPE European Innovation Council
Openalex Percentile: Top 27%
Wound Healing and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.