Intraoperative fluoroscopically assessment underestimates the posterior tibial slope in open‐wedge high tibial osteotomy
Purpose: To compare intraoperative and postoperative posterior tibial slope (PTS) measurements and determine whether unintended postoperative changes occur relative to preoperative values. Methods: A total of 79 patients (81 knees) underwent open-wedge high tibial osteotomy (owHTO) using patient-specific instrumentation (PSI) for varus malalignment were included. PTS was assessed pre, intra and postoperatively on short lateral knee radiographs using standardised calibrated software. The hip-knee-ankle angle (HKA) and the medial proximal tibia angle (MPTA) were measured pre and postoperatively on weight-bearing long leg radiographs (LLR). Results: < 0.001). Conclusion: Intraoperative PTS measurements significantly underestimated postoperative PTS, by a mean of 1.8°, indicating that visual intraoperative assessment based on fluoroscopy should be interpreted with caution when used to evaluate postoperative PTS. Level of Evidence: Level IV.
Authors
- Lukas Jud (ORCID: https://orcid.org/0000-0001-8128-3927)
- Georgios Neopoulos (ORCID: https://orcid.org/0000-0002-1928-5021)
- Patrizia Sieber
- Lazaros Vlachopoulos
- Alexander Berger
- Sandro F. Fucentese
Institutions
- Universitätsklinik Balgrist (CH)
Publication Details
- Journal
- Journal of Experimental Orthopaedics
- Published
- 2026-04-01
- DOI
- https://doi.org/10.1002/jeo2.70723
- Primary Topic
- Total Knee Arthroplasty Outcomes
- Type
- article
- Field-Weighted Citation Impact