Image Quality Advancements in Low-Dose Pediatric CT Using Super-Resolution Deep-Learning Reconstruction

The objective of the study is to assess the impact of super-resolution deep-learning reconstruction (SR-DLR) on image quality in low-dose thin-slice pediatric abdominal CT. Thirty-eight children (< 10 years; median age, 2.0 [IQR: 0.0-3.8] years) who had available low-radiation abdominal CT data were retrospectively analyzed. The mean size-specific dose estimate was 1.71 ± 0.38 mGy. From the raw datasets, 0.5-mm images were generated using SR-DLR developed for helical body imaging as well as hybrid-iterative reconstruction (hybrid-IR) and conventional deep-learning reconstruction (C-DLR), with matrices of 1024, 512, and 512, respectively. Quantitative assessments included measurements of image noise and contrast-to-noise ratio (CNR). Image noise characteristics were evaluated using the noise power spectrum (NPS), while edge sharpness was evaluated based on the edge-rise slope (ERS). For qualitative evaluation, noise magnitude, texture, sharpness, and small structure delineation were ranked among three reconstructions (1 = worst, 3 = best). Diagnostic confidence was scored with a five-point scale (1 = undiagnostic, 5 = most confident). Quantitative and qualitative data were compared among hybrid-IR, C-DLR, and SR-DLR. SR-DLR showed the greatest noise reduction and the highest CNR, outperforming the other reconstructions (p < 0.001). SR-DLR also achieved the highest ERS and maintained the lowest noise throughout the full range of spatial frequencies without a shift toward lower frequency. Subjective scores aligned with these quantitative findings, with SR-DLR consistently achieving the highest scores across all qualitative metrics (all p < 0.001). In conclusion, SR-DLR with 1024-matrix for helical body imaging enhanced sharpness and reduced noise in low-dose thin-slice pediatric abdominal CT, outperforming hybrid-IR and C-DLR in small structure delineation and overall diagnostic quality.

Authors

Institutions

Publication Details

Journal
Journal of Imaging Informatics in Medicine
Published
2026-04-14
DOI
https://doi.org/10.1007/s10278-026-01929-9
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Image Quality Advancements in Low-Dose Pediatric CT Using Super-Resolution Deep-Learning Reconstruction

T Inoue, Masafumi Kidoh, Yoshinori Funama, Takafumi Emoto et al.
Journal of Imaging Informatics in Medicine
Radiation Dose and Imaging
article

Image Quality Advancements in Low-Dose Pediatric CT Using Super-Resolution Deep-Learning Reconstruction

T Inoue, Masafumi Kidoh, Yoshinori Funama, Takafumi Emoto, Takeshi Nakaura, Yuya Ito, Yasunori Nagayama, Hiroko Ueda, Hiroto Takamure, Yutaka Chiba, Seitaro Oda, Toshinori Hirai, Naoki Kobayashi
article en

Abstract

The objective of the study is to assess the impact of super-resolution deep-learning reconstruction (SR-DLR) on image quality in low-dose thin-slice pediatric abdominal CT. Thirty-eight children (< 10 years; median age, 2.0 [IQR: 0.0-3.8] years) who had available low-radiation abdominal CT data were retrospectively analyzed. The mean size-specific dose estimate was 1.71 ± 0.38 mGy. From the raw datasets, 0.5-mm images were generated using SR-DLR developed for helical body imaging as well as hybrid-iterative reconstruction (hybrid-IR) and conventional deep-learning reconstruction (C-DLR), with matrices of 1024, 512, and 512, respectively. Quantitative assessments included measurements of image noise and contrast-to-noise ratio (CNR). Image noise characteristics were evaluated using the noise power spectrum (NPS), while edge sharpness was evaluated based on the edge-rise slope (ERS). For qualitative evaluation, noise magnitude, texture, sharpness, and small structure delineation were ranked among three reconstructions (1 = worst, 3 = best). Diagnostic confidence was scored with a five-point scale (1 = undiagnostic, 5 = most confident). Quantitative and qualitative data were compared among hybrid-IR, C-DLR, and SR-DLR. SR-DLR showed the greatest noise reduction and the highest CNR, outperforming the other reconstructions (p < 0.001). SR-DLR also achieved the highest ERS and maintained the lowest noise throughout the full range of spatial frequencies without a shift toward lower frequency. Subjective scores aligned with these quantitative findings, with SR-DLR consistently achieving the highest scores across all qualitative metrics (all p < 0.001). In conclusion, SR-DLR with 1024-matrix for helical body imaging enhanced sharpness and reduced noise in low-dose thin-slice pediatric abdominal CT, outperforming hybrid-IR and C-DLR in small structure delineation and overall diagnostic quality.

Journal of Imaging Informatics in Medicine
Canon (Japan) (JP), Kumamoto University Hospital (JP), Canon Medical Systems Corporation (Japan) (JP), Kumamoto University (JP)
Japan Society for Aeronautical and Space Sciences, Kumamoto University
Openalex Percentile: Top 12%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.